- F
- L
- E
- X
Pressure, piezoresistive.
Diaphragm seal.
Application: pressure/level.
Membrane: metal, welded.
Process connection: minimum oil volume.
:: Minimized temperature effect.
:: High reliability through process
monitoring.
:: Enhanced mechanical integrity.
:: Modular.
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Absolute and gauge pressure
-
Characteristic / Application
Digital transmitter with piezoresistive sensor and diaphragm seal
Modular transmitter
Long term stability
Minimum oil volume
Enhanced safety via self diagnostic functions
Secondary process barrier -
Specialities
Diagnostic functionalities
Different languages in software -
Supply / Communication
4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC -
Accuracy
0,075% + influence of diaphragm seal
-
Long term stability
0,05% of URL/year
-
Ambient temperature
-50°C...85°C
(-58°F...185°F) -
Process temperature
-70°C...400°C
(-94°F...752°F) -
Process pressure absolute / max. overpressure limit
1050bar (15,200psi)
-
Pressure measuring range
400 mbar...400 bar
(6 psi...6000 psi) -
Main wetted parts
Alloy C276
316L
Monel
Tantalum
PTFE-Foil -
Process connection
Threads
Flanges (DIN, ASME, JIS) with flush membrane
Tri-Clamp ISO02852
Hygienic connections -
Max. measurement distance
7000m (22.966ft) H2O
-
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC
-
Safety approvals
SIL
-
Design approvals
EN 10204-3.1
NACE MR0175, MR0103 -
Hygienic approvals
3A, EHEDG
-
Marine approval
GL/ ABS
-
Options
HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing -
Successor
PMP71B
-
Application limits
Measuring cell: Metal
welded
If pressurized, possibly
use differential pressure
meas-urement with two
pressure transmitters
(electronic dp). Observe
ratio head pressure :
hydrostatic pressure
-
Measuring principle
Absolute and gauge pressure
-
Characteristic
Digital transmitter with piezoresistive sensor and diaphragm seal
Modular transmitter
Long term stability
Minimum oil volume process connection
Enhanced safety via self diagnostic functions
Secondary process barrier -
Supply voltage
4...20 mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex) -
Reference Accuracy
0,075% + influence of diaphragm seal
-
Long term stability
0.05 % of URL/ year
0.07 % of URL/ 5 years
0.1 % of URL/ 10 years -
Process temperature
-70°C...400°C
(-94°F...752°F) -
Ambient temperature
-50°C...85°C
(-58°F...185°F) -
Measuring cell
400 mbar...400 bar
(6 psi...6000 psi)
relative/ absolute -
Smallest calibratable span
5 mbar (0.075 psi)
-
Vacuum resistance
10 mbar (0.15 psi)
-
Max. Turn down
100:1
-
Max. overpressure limit
1050 bar (15.750 psi)
-
Process connection
Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, NPT1/2...NPT1
Flange:
DN25...DN100,
ASME 1"...4",
JIS 10K
Diaphragm seal -
Process connection hygienic
Tri-Clamp
DIN11851
NEUMO
Varivent
SMS
DRD
Universal adapter -
Material process membrane
316L, AlloyC,
Tantal
Rhodium> Gold
PTFE -
Material gasket
None, diaphragm welded
-
Fill fluid
Silicone oil,
Inert oil,
Vegetable oil,
High temperature oil,
Low temperature oil, -
Material housing
Die-cast aluminum,
AISI 316L -
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC
-
Safety approvals
SIL
-
Design approvals
EN10204-3.1
NACE MR0103 -
Hygienic approvals
3A, EHEDG
-
Marine approvals
GL/ ABS
-
Specialities
Diagnostic functions
TempC Membrane -
Successor
PMP71B
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products