Proline Promass F 200
Coriolis flowmeter
Robust flowmeter with genuine loop-powered technology
Promass F has a long standing reputation as a highly accurate device. It is suited for broadest range of applications. Promass F 200 offers in addition genuine, industry-compliant two-wire technology. This enables seamless system integration into existing infrastructures. Additional advantages are high operational safety in hazardous areas thanks to an intrinsically safe design (Ex ia) and process safety at all times ensured by Heartbeat Technology.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F) -
Max. process pressure
PN 100, Class 600, 63K
-
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 ; Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
-
Quick selection
Individual configuration
-
Benefits
Highest process safety – immune to fluctuating and harsh environments
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in/outlet run needs
Convenient device wiring – separate connection...
-
Field of application
Measuring principle operates independently of physical fluid properties such as viscosity or density
Highest measurement performance for liquids and gases in a wide range of applications
Device properties
Mass flow: measured error ±0.1 %
Medium...
Documents / Manuals / Software
-
Proline Promass F 200
Coriolis flowmeter
Technical Information (TI) -
Proline Promass F 200
Coriolis flowmeter
HARTOperating Instruction (BA) -
Proline Promass F 200
Coriolis flowmeter
FOUNDATION FieldbusOperating Instruction (BA) -
Proline Promass F 200
Coriolis flowmeter
PROFIBUS PAOperating Instruction (BA) -
Proline Promass 200
PROFIBUS PA
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 200
FOUNDATION Fieldbus
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 200
HART
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass F 200
Brief Operating Instructions
Coriolis flowmeter
Short Instruction (KA)09/15English -
Proline 200
FOUNDATION Fieldbus
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 200
PROFIBUS PA
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 200
HART
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline Promass
Brief Operating Instructions
Proline Promass
Part 1 of 2
Coriolis sensorShort Instruction (KA)04/17English -
Proline Promass F
Brief Operating Instructions
Coriolis sensor
Short Instruction (KA)02/17English -
Replacing the I/O-Module
Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200
Installation Instructions (EA) -
Sealing set
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Installation Instructions (EA) -
Replacing the display module
Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50Installation Instructions (EA) -
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Installation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Housing filter
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Bus plug FF
Installation Instructions
Promag 53, 55, Promag 200, Promass 83, Promass 200, Prowirl 72, 73,
Prowirl 200, Prosonic Flow 92, 93Installation Instructions (EA) -
Replacing the transmitter
Installation Instructions
Promass 200/TB2, Prosonic Flow B 200, Promag 200
Installation Instructions (EA) -
Replacing the main electronics module
Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200
Installation Instructions (EA) -
Transmitter electronics FHX50
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Cover
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Installation Instructions (EA) -
Terminal set
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Replacing the sensor
Installation Instructions
Promass 200/TB2
Installation Instructions (EA) -
I/O module
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Set housing security clamp
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Proline Promass 200
INMETRO:
Ex nA IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promass 200
INMETRO:
Ex d[ia] IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promass 200
NEPSI:
Zone 1, Zone 0/1, Zone 21
Ex d version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 200
ATEX: II2G, II1/2G, II2D
IECEx: Zone 1, Zone 0/1, Zone 21
Ex d Version
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 200
NEPSI:
Zone 1, Zone 0/1, Zone 21
Ex i version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 200
ATEX: II2G, II1/2G, II2D
IECEx: Zone 1, Zone 0/1, Zone 21
Ex i Version
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 200
Class I, Division1; Zone 0 for IS
(Ex i Intrinsically safe version)
Safety Instructions
Safety instructions for explosion-hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 200
INMETRO:
Ex ia IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promass 200
NEPSI:
Zone 2
Ex nA and Ex ic version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 200
Class I, Division 1; Zone 1 for XP
(Ex d Flameproofed version)
Safety Instructions
Safety instructions for explosion-hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 200
ATEX: II3G, II1/3G
IECEx: Zone 2, Zone 0/2
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Heating jacket
For Promass F Coriolis flowmeters
Special Documentation
Heating jacket
For Promass F Coriolis flowmetersSpecial Documentation (SD) -
Proline Promass 200
HART
Heartbeat Verification application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Levelflex FMP5x, Micropilot FMR5x
Weather protection cover
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Proline Promass 100, 200
Proline Cubemass 100
Special Documentation
Medium temperature range
Special Documentation (SD) -
Proline Promass 200
PROFIBUS PA
Heartbeat Verification application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass
Information on the Pressure Equipment Directive
Special Documentation
Coriolis mass flow measuring system
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Proline Promass 200
Heartbeat Technology Application Package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 200
Functional Safety Manual
Special Documentation (SD) -
Proline Promass 200
FOUNDATION Fieldbus
Heartbeat Verification application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Promass 200
Manufacturer information regarding software
updates (NE 53)
New software version:
Promass 200 HART: 1.02.00Manufacturer Information (MI) -
Proline Promass 200
Manufacturer information regarding firmware
updates (NE
53)
New firmware version:
Promass 200 HART: 1.03.00Manufacturer Information (MI) -
Proline Promass 200
Manufacturer information regarding software
updates (NE 53)
New software version:
Promass 200 HART: 1.01.02Manufacturer Information (MI) -
Proline Promass 200
Manufacturer information regarding software
updates (NE 53)
New software version:
Promass 200 HART: 1.01.01Manufacturer Information (MI) -
Proline Promass 200
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promass 200 PROFIBUS PA: 1.01.01Manufacturer Information (MI) -
Proline Promass 200
Manufacturer information regarding firmware
updates (NE53)
New firmware version:
Promass 200 HART: 1.04.01Manufacturer Information (MI) -
Proline Promass 200
Coriolis flow measurement in efficient two-wire technology for the
chemical industry – For the highest operational safety round the clockInnovations (IN)07/13English -
Proline Promass 200
Кориолисовые расходомеры с питанием по сигнальной цепи
Innovations (IN)07/12Russian -
Proline Promass 200
American version: Coriolis flow measurement in efficient two-wire
technology for the
chemical industry – For the highest operational safety round the clockInnovations (IN)03/16English -
GSD Single, GSD_EH_PA_FL_Promass200_0x155F_0x01_0x01, 11.11.2016 (Flow, P
romass 200, 0x155F)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_EH_PA_FL_Promass200_0x155F_0x02_0x01_PALIB, 17.08.2015 (Flow, Promass 200)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass200_0x0054_0x04_0x01, 12.05.2014 (Flow, Promass 200, 0x0054)
HART,
PDM Version: 6.1, 8.1 SP1Electronic Data Description (EDD)1.03.00Language neutral -
EDD Single, PDM_HART_FL_Promass200_0x0054_0x03_0x01, 31.03.2014 (Flow, Promass 200, 0x0054)
HART,
PDM Version: 6.0 SP5, 6.1Electronic Data Description (EDD)1.02.00Language neutral -
EDD Single, AMS12_HART_FL_Promass200_0x0054_0x04_0x01, 21.08.2019 (Flow, Promass 200, 0x0054)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass200_0x0054_0x05_0x01, 21.08.2019 (Flow, Promass 200, 0x0054)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass200_0x0054_0x03_0x01, 21.08.2019 (Flow, Promass 200, 0x0054)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass200_0x0054_0x04_0x01, 20.05.2015 (Flow, Promass 200)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Promass200_0x1054_0x01_0x02, 14.03.2018 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 6Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass200_0x0054_0x05_0x01, 03.08.2015 (Flow, Promass 200)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promass200_0x0054_0x05_0x01, 21.08.2019 (Flow, Promass 200, 0x0054)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promass200_0x155F_0x01_0x01, 18.09.2014 (Flow, Promass 200, 0x155F)
PROFIBUS PA,
PDM Version: 6.0 SP5, 6.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Promass200_0x1054_0x01_0x02, 14.03.2018 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
AMS Version: 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promass200_0x155F_0x02_0x01, 17.08.2015 (Flow, Promass 200)
PROFIBUS PA,
PDM Version: 6.1, 8.2 SP 1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Promass200_0x1054_0x01_0x02, 20.08.2019 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promass200_0x0054_0x04_0x01, 21.08.2019 (Flow, Promass 200, 0x0054)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Promass200_0x1054_0x01_0x02, 14.03.2018 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
AMS Version: 10.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promass200_0x0054_0x03_0x01, 21.08.2019 (Flow, Promass 200, 0x0054)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass200_0x0054_0x05_0x01, 03.08.2015 (Flow, Promass 200)
HART,
PDM Version: 6.1, 8.2 SP 1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Promass200_0x1054_0x01_0x02, 22.08.2019 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
AMS Version: 12.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS_HART_FL_Promass200_0x0054_0x05_0x01, 03.08.2015 (Flow, Promass 200)
HART,
AMS Version: 12.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_FF_FL_Promass200_0x1054_0x01_0x01, 22.01.2015 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass200_0x0054_0x03_0x01, 20.05.2015 (Flow, Pr
omass 200)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promass200_8x2B_8x2C_PA_FW1_01_zz_Dev_Rev_2, 21.10.2020 (Flow, Promass 200, 0x155F)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.7.0.236Language neutral -
DTM Single, Promass200_8x2B_8x2C_HART_FW1_04_zz_Dev_Rev_5, 27.10.2020 (Flow, Promass 200, 0x0054)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11Device Type Manager (DTM)1.5.0.1133Language neutral -
DTM Single, Promass_200_8x2B_8x2C_FF_FW_1_00_zz_Dev_Rev_1, 22.10.2020 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.3.0.150Language neutral -
DTM Single, Promass200_8x2B_HART_FW1_03_zz_Dev_Rev_4, 27.10.2020 (Flow, Promass 200, 0x0054)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11Device Type Manager (DTM)1.2.0.1099Language neutral -
DTM Single, Promass200_8x2B_HART_FW1_02_zz_Dev_Rev_3, 26.10.2020 (Flow, Promass 200, 0x0054)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05Device Type Manager (DTM)1.0.0.0Language neutral -
DTM Single, Promass200_8x2Bxx_PA_FW1_00_zz_Dev_Rev_1, 21.10.2020 (Flow, Promass 200, 0x155F)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.0.0.0Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Library, PRM_FF_Package_Flow_1_05_00, 22.07.2015 (Flow)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.12Faceplate1.05.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass200_0x0054_0x03_0x01, 31.03.2014 (Fl
ow, Promass 200, 0x0054)
HART,
Plant Resource Manager Version: R3.05Faceplate1.02.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass200_0x0054_0x05_0x01, 03.08.2015 (Flow, Promass 200)
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_FF_FL_Promass200_0x1054_0x01_0x01, 22.01.2015 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Note Single, Release_Notes_Promass200_FF_0x1054_0x01, 23.08.2018 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 15.05.2020 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 15.05.2020 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Dosimass, Dosimass OEM, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F
Product Code: 8RE-, 8PE-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 8CE-, 8BE-, 84F-, 83F-, 83E-, 80F-, 80E-, 40E-
Declaration Number: HE_01000_03.18
Manufacturer Specification: Food hygieneManufacturer DeclarationGerman , English -
Dosimass OEM, Promass 40, Promass 80, Promass 83, Promass 84, Promass A, Promass E, Promass F, Promass Q
Product Code: 8E3B-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8F5B-, 8PE-, 8Q3B-, 8Q5B-, 8RE-, O8E1B-, O8E1C-, O8E3B-, O8E5B-, O8F1B-, O8F3B-, O8F5B-, O8Q3B-, O8Q5B-, 8E2B-, 8E1C-, 8E1B-, 8BE-, 8A5C-, 8A5B-, 8A3C-, 8A3B-, 8A2B-, 8A1B-, 84F-, 84A-, 83F-, 83E-, 83A-, 80F-, 80E-, 80A-, 40E-
Declaration Number: HE_00351_04.16
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationEnglish -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Declaration Number: EC_00236_04.16EU DeclarationGerman , English , fr -
Promass 80, Promass 83, Promass 84, Promass F, Promass Q
Product Code: O8F1B-, 8Q5B-, 8Q3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 84F-, 83F-, 80F-
Declaration Number: EC_00062_05.15EU DeclarationGerman , English , fr -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Declaration Number: EC_00237_05.16EU DeclarationGerman , English , fr -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Declaration Number: EC_00238_04.16EU DeclarationGerman , English , fr -
Promass E, Promass F
Product Code: 8E2B-, 8E2C-, 8F2B-
Declaration Number: EC_00060_03.15EU DeclarationGerman , English , fr -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRussian -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promass X, Promass F, Promass E, Promass 83, Promass P, Promass S, Promass I, Promass O, Promass H, Promass A, Promass 84, Promass 80, Promass 40
Product Code: 8E1B-, 83F-, 83E-, 83H-, 83I-, 83P-, 83M-, 83S-, 83A-, 8F2B-, 8F1B-, 8I1B-, 8S1B-, 83O-, 83X-, 8A1B-, 80F-, 80E-, 80H-, 8E2B-, 80I-, 84F-, 80P-, 80S-, 8O1B-, 80A-, 8P5B-, 8I5B-, 8H5B-, 8S5B-, 8F5B-, 8F3B-, 8E3B-, 8E5B-, 8S3B-, 8I3B-, 8O3B-, 8P3B-, 8H3B-, 8X3B-, 84A-, 8A5B-, 8A3B-, 40E-, 8X5B-, 8S1C-, 8E2C-, 84X-, 8A5C-, 8A3C-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex nAExplosion ProtectionPortuguese -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 3 G, II 1/3 G
Protection: Ex ic [ia Ga], Ex ic [ia], Ex nAExplosion ProtectionEnglish -
Promass E, Promass F, Promass A
Product Code: 8E2B-, 8F2B-, O8E2B-, O8F2B-, 8A2B-, 8E2C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D/T6...T1
Protection: DIP, ISExplosion ProtectionEnglish -
Promass E, Promass F
Product Code: 8E2B-, 8F2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1
Protection: Ex d [ia]Explosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ic, Ex ic [ia Ga], Ex ic [ia], Ex nA, Ex nA [ia Ga]Explosion ProtectionEnglish -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Region/Country: South Africa
Approval Agency: MTEx
Category: zone 2
Protection: Ex ic, Ex ic [ia Ga], Ex ic [ia], Ex nA, Ex nA [ia Ga], Ex ecExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: Japan
Approval Agency: CML
Protection: Ex d [ia]Explosion ProtectionJapanese -
Promass A, Promass E, Promass F, Prosonic Flow B
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-, 9B2B-, O9B2B-
Region/Country:
Approval Agency:
Protection: Ex ia, Ex ic, Ex nA, Ex tb, Ex ec, Ex dbExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex d [ia], Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promass E, Promass F
Product Code: 8E2B-, 8E2C-, 8F2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2
Protection: Ex ic IIC T6...T1 Gc, Ex ic [ia Ga] IIC T6...T1 Gc, Ex nA II T6...T1 Gc, Ex nA [ia Ga] IIC T6...T1 GcExplosion ProtectionEnglish -
Promass E, Promass F
Product Code: 8E2B-, 8E2C-, 8F2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 0,1, zone 20,21
Protection: Ex ia IIC T6...T1 Ga/Gb, Ex tD A20/A21 IP6X Txxx°C, Ex iaD 20/21 Txxx°C, Ex d [ia Ga] IIC T6...T1 Ga/GbExplosion ProtectionEnglish -
Prowirl R, Prowirl O, Prowirl F, Prowirl D, Prowirl C, Prosonic Flow B, Promass F, Promass E, Promass A, Promag P, Promag H, Promag E
Product Code: O9B2B-, O5P2B-, O5H2B-, 9B2B-, 8F2B-, 8E2C-, 8E2B-, 8A2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-, 5P2B-, 5H2B-, 5E2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8E2C-, 8F2B-, 8E2B-, 8A2B-
Region/Country: Russia
Protection: Ex tb [ia Da] IIIC Txxx°C Db, Ex nA [ia Ga] IIC T6...T1 Gc, Ex d [ia Ga] IIC T6...T1 Ga/Gb, Ex d [ia Ga] IIB T6...T1 Ga/Gb, Ex tb IIIC Txxx°C Db, Ex nA IIC T6...T1 Gc, Ex ic [ia] IIC T6...T1 Ga/Gc, Ex ic [ia] IIB T6...T1 Ga/Gc, Ex ic IIC T6...T1 Gc, Ex ic IIB T6...T1 Gc, [Ex ia] IIC T6...T1 Gb, [Ex ia] IIC T6...T1 Ga/Gb, [Ex ia] IIB T6...T1 Ga/GbExplosion ProtectionRussian -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: China
Approval Agency: NEPSI
Category: zone 0,1, zone 20,21
Protection: Ex iaD 20/21 Txxx°C, Ex ia, Ex tD A20/A21 IP6X, Ex d [ia Ga]Explosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 2 D, II 2 G, II 1/2 G, II 2(1) D
Protection: Ex d [ia], Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1
Protection: Ex ia, Ex d [ia Ga]Explosion ProtectionEnglish -
Promass E, Promass F
Product Code: 8E2B-, 8F2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1
Protection: Ex iaExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 1
Protection: Ex iaExplosion ProtectionPortuguese -
Promass E, Promass F, Promass A
Product Code: 8E2B-, 8F2B-, O8E2B-, O8F2B-, 8A2B-, 8E2C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D/T6...T1, II,III/1/E,F,G/
Protection: DIP, XP/ISExplosion ProtectionEnglish -
Promass E, Promass F
Product Code: 8E2B-, 8F2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1
Protection: Ex iaExplosion ProtectionEnglish -
Promass E, Promass F, Promass A
Product Code: 8E2B-, 8F2B-, O8E2B-, O8F2B-, 8A2B-, 8E2C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D/T6...T1, II,III/1/E,F,G/
Protection: DIP, NIExplosion ProtectionEnglish -
Promass E, Promass F
Product Code: 8E2B-, 8E2C-, 8F2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1
Protection: Ex ia IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 GbExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2
Protection: Ex ic, Ex nAExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 2 D, II 2 G, II 1/2 G, II 2(1) D
Protection: Ex d [ia], Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Region/Country: South Africa
Approval Agency: MTEx
Category: zone 1, zone 21, zone 0,1
Protection: Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promass 80, Promass 83, Promass 84, Promass F
Product Code: O8F5B-, O8F3B-, O8F1B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 84F-, 83F-, 80F-
Region/Country: International
Approval Agency: DTUHygienic EquipmentEnglish -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
Promass F, Promass E
Product Code: 8E2B-, 8F2B-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: 1.00.01Fieldbus ConformanceEnglish -
Promass E, Promass F
Product Code: 8E2B-, 8F2B-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFILE 3.02Fieldbus ConformanceEnglish -
Promass E, Promass F
Product Code: 8E2B-, 8F2B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: DEVICE REV. 5, HART 7Fieldbus ConformanceEnglish -
Promass F, Promass E, Promass A, Promass I, Promass P, Promass S
Product Code: 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8S1B-, 8F2B-, 8E2B-, 8E1C-, 8S1C-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A № 55235_1MetrologyRussian -
Promass F, Promass E, Promass O, Promass A, Promass X, Promass Q, Promass I, Promass P, Promass S, Promass H, Promass G, Promass 84, Promass 83, Promass 80, Promass 40
Product Code: 8Q5B-, 8F5B-, 8O5B-, 8E5B-, 8X5B-, 8I5B-, 8S5B-, 8P5B-, 8H5B-, 8Q3B-, 8A5B-, 8F3B-, 8O3B-, 8E3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8H1B-, 8O1B-, 8S1B-, 8G1B-, 8S1C-, 8F2B-, 8E2B-, 83F-, 83E-, 8E1C-, 83A-, 83I-, 83S-, 83H-, 83P-, 8E2C-, 80F-, 83O-, 83X-, 80E-, 80A-, 80I-, 80P-, 80S-, 40E-, 80H-, 84X-, 84O-, 84F-, 84A-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6721MetrologyRussian -
Promass 83, Promass E, Promass F, Promass P
Product Code: 83F-, 8E1B-, 8F1B-, 8F2B-, 8P1B-
Region/Country:
Approval Agency: MSST
Approval Number: MSST_2248MetrologyRussian -
Promass A, Promass E, Promass F
Region/Country:
Heartbeat TechnologyGerman , English
Accessories / Spare parts
-
-
Nr 34 Order code 71108602
I/O module Flow, 2-wr. 2x4-20mA,HART, Ex
Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: FTM50/FTM51/FTM52. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 34 Order code 71164940
I/O module, 2-wire, PA/FF, PFS, Ex, V2
Non-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS=switch output. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass 200, Prowirl 200, Promag 200.
-
-
-
Order code 71128617
Overvoltage protection (OVP10),1-Channel
4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71128619
Overvoltage protection (OVP20),2-Channel
4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71197334
Transmitter electronics FHX50
Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200.
-
Order code
Remote display FHX50 please order with separate order structure.
-
Order code 71296840
M12-female plug connector, VA
To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.
-
-
-
Nr 30 Order code XPD0001-
-
-
-
Order code 71206552
-
Order code 71206554
-
Order code 71206555
-
-
-
Nr 34 Order code XPD0015-
-
-
-
Order code 71206556
-
-
-
Nr 37 Order code 71110280
Terminal set 2-wire, I/O module
Consists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 34 Order code XPD0016-
I/O module, 2-wire, 4-20mA,HART, PFS, Ex
Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.
-
-
-
Nr 40 Order code XPD0024-
Display module, SD02, push buttons
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.
-
Nr 40 Order code XPD0025-
Display module, SD03, Touch Control
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.
-
-
-
Nr 20 Order code 71110281
Cover GT18 316L, HNBR
Material: 316L. O-ring, EPDM, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 20 Order code 71110282
Cover GT18 316L, sight glass, HNBR
Material: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
-
-
Nr 25 Order code 71110291
Cover GT18 316L, terminal Ex, HNBR
Material: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 25 Order code 71110284
Cover GT18 316L, terminal Ex d, HNBR
Material: 316L. O-ring EPDM /PTFE coated. Usage: terminal compartment Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 25 Order code 71185516
Cover GT18 316L, Terminal, OVP, HNBR
Material: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMP54/FMP56/FMP57, FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Prowirl 200.
-
-
-
Nr 20 Order code 71110299
Cover GT20 Alu, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 20 Order code 71110297
Cover GT20 Alu, sight glass, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 25 Order code 71110301
Cover GT20 Alu, Terminal Ex, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71110302
Cover GT20 Alu, Terminal Ex d, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71185517
Cover GT20 Alu, Terminal, OVP, HNBR
Material: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 71115505
Kit 10 ext. M20x1,5/G 1/2" (plug brass)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 71115509
Kit 10 ext. M20x1,5/NPT1/2"(plug brass)
-
Nr 15 Order code 50098037
Kit Cable gland Profibus PA
-
Nr 15 Order code 50094984
Kit Cable gland Found. Fieldbus
-
-
-
Nr 65 Order code 71110303
Sealing set GT18/GT19/GT20, EPDM, HNBR
Consists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 19 Order code 71115174
Housing filter 316L, GT18, 1 set
Consists of: 2x filter plug metall 316L. 1x pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 19 Order code 71115175
Housing filter Brass/Ni GT19/20, 1 set
Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 17 Order code 71115176
Set housing securing clamps
Usage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Order code 71162242
Weather prot. cover GT18/GT19/GT20, 316L
Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/ FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 8X2BXX-
-
Order code 8X2BX1-
-
Order code XPRFID-
-
Order code DK8003-
-
-
Predecessor