Proline Promag H 500
Electromagnetic flowmeter
Specialist for hygienic applications, as remote version with up to 4 I/Os
Promag H is the preferred sensor for hygienic applications with highest requirements in the food and beverage and life sciences industries. With its innovative remote transmitter Promag H 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures compliance and process safety at all times.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
0.06 dm³/min to 600 m³/h (0.015 gal/min to 2 650 gal/min)
-
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
-
Max. process pressure
PN 40, Class 150, 20K
-
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum
-
Quick selection
Individual configuration
-
Benefits
Multivariable measurement for flow, temperature and conductivity
Flexible installation concept – numerous hygienic process connections
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-free – no moving parts
...
-
Field of application
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Dedicated to demanding applications in the food and beverage as well as in life sciences industries
Device properties
Liner made of PFA
Sensor...
Documents / Manuals / Software
-
Proline Promag H 500
Electromagnetic flowmeter
Technical Information (TI) -
Proline Promag H 500
HART
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag H 500
FOUNDATION Fieldbus
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag H 500
PROFIBUS DP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag H 500
Modbus RS485
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag H 500
PROFIBUS PA
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag H 500
EtherNet/IP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag H 500
PROFINET
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 500
EtherNet/IP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 500
FOUNDATION Fieldbus
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 500
PROFIBUS PA
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 500
PROFIBUS DP
Description of Device Parameters
Electromagnetic flowmeter
Proline Promag 500
PROFIBUS DPDevice Parameter (GP) -
Proline Promag 500
Modbus RS485
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 500
HART
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 500
PROFINET
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline 500
HART
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)08/16English -
Proline 500
PROFIBUS PA
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)08/16English -
Proline 500
Modbus RS485
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)08/16English -
Proline Promag
Brief Operating Instructions
Proline Promag
Part 1 of 2
Electromagnetic sensorShort Instruction (KA)04/17English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with
electromagnetic sensorShort Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with
electromagnetic sensorShort Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Proline Promag H
Brief Operating Instructions
Proline Promag H
Electromagnetic sensorShort Instruction (KA)02/17English -
Replacing the transmitter
Installation Instructions
, , Promag 500-digital
Installation Instructions (EA) -
Replacing the Components for the Transmitter
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Potting compound IP68
Promag 400 Remote Version, Promag 800 Remote Version, Promag 500, t-mass
500-digitalInstallation Instructions (EA) -
Activating application packages, switching the I/O function, upgrading
with additional I/O hardware
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Alteration to Display module, to Display module with WirelessHART or
Display module with WLAN
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the terminal connection
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing ISEM electronics module, ISEM extender, ribbon cable
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Pipe mounting set
Installation Instructions
Promag, Promass 500
Installation Instructions (EA) -
Replacing cover, O-ring, seal housing for transmitter wall mounting and
seal housing for the sensor side
Promag, Promass 500, 500-digital, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing transmitter Promag, Promass 500 digital
Installation Instruction
Promag 500 digital, Promass 500 digitalInstallation Instructions (EA) -
Alteration with correspondent I/O hardware for HART, Modbus
Promag, Promass 300, 500, 500-digital
Installation Instructions (EA) -
Replacing the Seal Housing
Installation Instructions
Promag 100, Promag 500-digital
Installation Instructions (EA) -
Replacing the transmitter
Installation Instructions
Promag 500
Installation Instructions (EA) -
Replacing cover, O-ring cover, Interface gasket
Promag, Promass 300, 500, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Weather Protection
Promag, Promass 300, 500, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Replacing Small Parts
Promag 400 , Promag 800 Index B, Cubemass, Promag 500, Promag, Promass,
Prosonic Flow, t-mass 500-digitalInstallation Instructions (EA) -
Kit wireless antenna for extended range
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the S-DAT
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the Sensor
Promag, Promass, Prosonic Flow 500-digital
Installation Instructions (EA) -
Weather Protection
Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing the electronics
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing connection board
Installation Instructions
Promag, Promass 500
Installation Instructions (EA) -
Replacing the display module
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digital, DKX001–Installation Instructions (EA) -
Conversion Kit for Promag, Promass 300 Compact Version to Promag,
Promass 500 Remote Version
Installation Instructions
Promag, Promass 300, 500
Installation Instructions (EA) -
Replacing transmitter Promag, Promass 500
Installation Instructions
Promag 500, Promass 500Installation Instructions (EA) -
Replacement of parts for the sensor connection housing, remote version
Promag 400 Index C, Promag 500, Promag, Promass, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Replacing Small parts
Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400 Index C,
Prosonic Flow E 100, Prosonic Flow E Heat, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Replacing RJ45-M12 Adapter
Proline 300, 500-digital
Installation Instructions (EA) -
Protective Cover connection compartment
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Pipe mounting set
Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing the Display Protection
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Proline Promag 500
EAC:
1Ex d e [ia Ga] IIC T6...T5 Gb X
1Ex e ia IIC T6...T1 Gb X
1Ex d [ia Ga] IIC T6...T5 Gb X
1Ex d ia IIC T6...T1 Gb X
2Ex nA nC [ic] IIC T5...T4 Gc X
2Ex nA nC IIC T5...T4 Gc X
Ex tb [ia Da] IIIC T85 °C Db XEx Safety Instructions (XA) -
Proline Promag 500
ATEX:
II2G
II2D
IECEx:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 500
INMETRO:
Zona 1
Zona 2
Zona 21
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promag 500
Class I, Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 500
EAC:
2Ex nA ic IIC T6...T1 Gc X
2Ex nA nC [ic] IIC T5...T4 Gc X
2Ex nA nC IIC T5...T4 Gc XEx Safety Instructions (XA) -
Proline Promag 500
JPN:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 500
NEPSI:
Zone 2Ex Safety Instructions (XA) -
Proline Promag 500
NEPSI:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 500
ATEX:
II3G
IECEx:
Zone 2Ex Safety Instructions (XA) -
Proline Promag 500
Class I Zone 2
Class I Division 2Ex Safety Instructions (XA) -
Proline Promag 500
INMETRO:
Zona 2
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promag 500
Cl.I, II, III Div.1 for XP
(Ex d Flameproofed version)Ex Safety Instructions (XA) -
Proline Promag 500
EtherNet/IP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag H 300, 500
Promag H Redesign DN 02 - 25
Special Documentation
Promag H Redesign DN 02 - 25
Special Documentation (SD) -
Proline Promag 500
PROFINET
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 500
PROFINET
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
Modbus RS485
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
PROFIBUS PA
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 500
PROFIBUS DP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 500
Functional Safety Manual
Special Documentation (SD) -
Proline Promag 500
PROFIBUS DP
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
Modbus RS485
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 500
FOUNDATION Fieldbus
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 500
HART
OPC-UA Server application package
for IIoT and SCADA applications
Special Documentation
Special Documentation
OPC-UA Server
For IIoT and SCADA applicationsSpecial Documentation (SD) -
Proline Promag 500
HART
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
Connecting the connecting cable
Special Documentation
Connecting the connecting cable
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Display modules A309/A310
Display with WLAN interface
Special Documentation (SD) -
Proline Promag 500
EtherNet/IP
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
FOUNDATION Fieldbus
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Proline Promag 500
PROFIBUS PA
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 300 500
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promag 300 500 Modbus RS485: 1.01.01Manufacturer Information (MI) -
Proline Promag 300 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300 500 HART: 1.05.00Manufacturer Information (MI) -
Proline Promag 300 500
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promag 300 500 HART: 1.01.01Manufacturer Information (MI) -
Proline Promag 300 / 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300 / 500 PROFIBUS PA: 1.01.00Manufacturer Information (MI) -
Proline Promag 300/500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300/500 Modbus RS485: 1.05.00Manufacturer Information (MI) -
Proline Promag 300/500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300/500 PROFINET: 1.01.00Manufacturer Information (MI) -
Industrial Ethernet für Proline Durchflussmessgeräte
Die Systemintegration der Zukunft
Innovations (IN)12/17German -
Industrial Ethernet for Proline flowmeters
The system integration of the future
Innovations (IN)12/17English -
Proline 300/500
La technologie de mesure de débit orientée vers l’avenir
Innovations (IN)09/18fr -
Proline 300/500
La tecnologia di misura della portata orientata al futuro
Innovations (IN)05/16Italian -
Proline 300/500
La tecnología de medición de caudal del futuro
Innovations (IN)05/16Spanish -
Proline 300/500
American version: The future-oriented flow measuring technology
Innovations (IN)05/16English -
Proline 300/500
Technologie měření průtoku orientovaná na budoucnost
Innovations (IN)05/16Czech -
Proline 300/500
Die zukunftsweisende Durchfluss-Messtechnik
Innovations (IN)03/18German -
流量計 Proline 300/500
未来志向の流量測定技術
Innovations (IN)03/18Japanese -
Proline 300/500
The future-oriented flow measuring technology
Innovations (IN)03/18English -
Promag H500
Magnetisch-induktives Durchflussmessgerät getrennte Bauform zur
bidirektionalen
Messung von Flüssigkeiten mit einer Mindestleitfähigkeit von ≥ 5 μS/cm.Tender Text04/20German -
GSD Single, GSD_DP_FL_Promag_300500_0x1570_0x01_0x01, 04.06.2018 (Flow, Promag 300 500, 0x1570)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PA_FL_Promag300500_0x156C_0x02, 09.11.2018 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_EH_PA_FL_Promag300_500_0x156C_0x01_0x01, 08.08.2016 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promag300500_0x843C_0x02, 10.09.2019 (Flow, Promag 300 500, 0x843C)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promag300500_0x843C_0x01_0x01, 16.11.2017 (Flow, Promag 300 500, 0x843C)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EIP_FL_Promag_300500_0x103C_0x01_0x01, 09.01.2020 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.3Language neutral -
EDD Single, PDM_HART_FL_Promag300_500_0x003C_0x01_0x01, 09.08.2016 (Flow, Promag 300 500, 0x113C)
HART,
PDM Version: 6.1, 8.2.1, 9.0Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, PDM_PA_FL_Promag300_500_0x156C_0x01_0x01, 09.08.2016 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PDM Version: 6.1, 8.2.1, 9.0, 9.1Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, AMS12_0_HART_FL_Promag300_500_0x113C_0x02_0x01, 22.11.2018 (Flow, Promag 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN-CDIE_FL_Promag300_500_0x843C_0x01_0x01, 27.11.2017 (Flow, Promag 300 500, 0x843C)
PROFINET,
PDM Version: 8.2.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag300_500_0x113C_0x01_0x01, 20.08.2019 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag300_500_0x113C_0x06_0x01, 10.09.2019 (Flow, Promag 300 500, 0x113C)
HART,
Experion Version: R500
Field Device Manager Version: R500Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag300_500_0x113C_0x06_0x01, 25.09.2020 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Promag300500_0x103C_0x01_0x01, 29.09.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag300500_0x1570_0x01_0x01, 16.07.2018 (Flow, Promag 300 500, 0x1570)
PROFIBUS DP,
PDM Version: 8.2.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag300_500_0x003C_0x01_0x01, 09.08.2016 (Flow, Promag 300 500, 0x113C)
HART,
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag300_500_0x113C_0x02_0x01, 27.11.2017 (Flow, Promag 300 500, 0x113C)
HART,
PDM Version: 8.2.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag300_500_0x113C_0x02_0x01, 28.11.2017 (Flow, Promag 300 500, 0x113C)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FCx75_HART_FL_Promag300500_0x113B_0x01_0x01, 22.02.2017 (Flow, Promag 300 500, 0x113C)
HART, Package: Package, Variant: Variant
FC475 Version: 2.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag300_500_0x113C_0x06_0x01, 20.09.2019 (Flow, Promag 300 500, 0x113C)
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promag300_500_0x843C_0x01_0x01, 27.11.2017 (Flow, Promag 300 500, 0x843C)
PROFINET,
PDM Version: 8.2.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 10.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_HART_FL_Promag300_500_0x113C_0x02_0x01, 22.11.2018 (Flow, Promag 300 500, 0x113
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promag300_500_0x843C_0x02_0x01, 20.09.2019 (Flow, Promag 300 500, 0x843C)
PROFINET,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 11.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promag300500_0x156C_0x02_0x01, 18.01.2019 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PDM Version: 8.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag300_500_0x113C_0x06_0x01, 25.09.2020 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag300_500_0x113C_0x01_0x01, 20.08.2019 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promag_300_500_0x103C_FF_FW1_00_zz_Dev_Rev_01, 22.10.2020 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1
Plant Resource Manager Version: R3.20Device Type Manager (DTM)1.9.0.122Language neutral -
DTM Single, Promag_300_500_0x003C_FW_1_00_zz_Dev_Rev_1, 27.10.2020 (Flow, Promag 300 500, 0x113C)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1 SP4
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.8.0.139Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_00_zz_Dev_Rev_1, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.8.0.130Language neutral -
DTM Single, Promag_300_500_HART_FW_1_06_00_Dev_Rev_06, 27.10.2020 (Flow, Promag 300 500, 0x113C)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R500
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.285Language neutral -
DTM Single, Promag_300_500_MR4_FW_1_05_zz_Dev_Rev_06, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.230Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_05_zz_Dev_Rev_06, 04.10.2019 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.39.0.230Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_05_zz_Dev_Rev_06, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.230Language neutral -
DTM Single, Promag300500_PN-CDIE_FW_1_01_zz_Dev_Rev_02, 05.11.2020 (Flow, Promag 300 500, 0x843C)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.136Language neutral -
DTM Single, Promag_300_500_5x3x-5x5x_FW_1_01_zz_Dev_Rev_02, 21.10.2020 (Flow, Promag 300 500, 0x156
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0Device Type Manager (DTM)1.12.0.161Language neutral -
DTM Single, Promag_300_500_DP_FW_1_00_zz_Dev_Rev_01, 19.10.2020 (Flow, Promag 300 500, 0x1570)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0Device Type Manager (DTM)1.11.0.65Language neutral -
DTM Single, Promag_300_500_0x156C_FW_1_00_zz_Dev_Rev_1, 21.10.2020 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.11.0.104Language neutral -
DTM Single, Promag300500_PN-CDIE_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promag 300 500, 0x843C)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.65Language neutral -
DTM Single, Promag_300_500_EIP-CDIE_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.59Language neutral -
DTM Single, Promag_300_500_EIP_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Unity Pro XL Version: 11.1Device Type Manager (DTM)1.10.0.59Language neutral -
DTM Single, Promag_300_500_HART_FW_1_01_zz_Dev_Rev_02, 27.10.2020 (Flow, Promag 300 500, 0x113C)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.10.0.223Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_01_zz_Dev_Rev_02, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.207Language neutral -
DTM Single, Promag_300_500_MR4_FW_1_01_zz_Dev_Rev_02, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.207Language neutral -
AOP Single, RS_EIP_FL_Promag300500_0x103C_0x01_0x01_AOP, 28.08.2019 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
RA RSLogix 5000 Version: V20.04and later
RA Studio 5000 Version: V21 and laterAdd On Profile (AOP)1.10Language neutral -
Faceplate Single, PRM_HART_FL_Promag300_500_0x003C_0x01_0x01, 08.08.2016 (Flow, Promag 300 500, 0x1
HART,
Plant Resource Manager Version: R3.20Faceplate1.00.01Language neutral -
Faceplate Single, PRM_HART_FL_Promag300_500_0x113C_0x02_0x01, 28.11.2017 (Flow, Promag 300 500, 0x1
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.20Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag300_500_0x113C_0x06_0x01, 10.09.2019 (Flow, Promag 300 500, 0x1
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 15.05.2020 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 15.05.2020 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_ProfiNet, 15.05.2020 (Flow)
PROFINET,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 15.05.2020 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 15.05.2020 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_DP, 15.05.2020 (Flow)
PROFIBUS DP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Promag P, Promag H, Promag E, Promag 55, Promag 53, Promag 50, Promag 10, Ersatzteil, Dosimag OEM, Dosimag
Product Code: 5P5B-, 5P3B-, 5H5B-, 5H3B-, 5P1B-, 5H1B-, 53H-, 53P-, 50H-, 5P2B-, 5H2B-, 50P-, 55S-, 55H-, O5H1B-, DKH-, DK5HB-, DK5G-, 5SH-, 5RH-, 5CH-, 5BH-, 5DH-, 10H-
Declaration Number: HE_01074_01.18Manufacturer DeclarationGerman , English -
Dosimag, Dosimag OEM, Promag 10, Promag 50, Promag 53, Promag 55, Promag H
Product Code: DDA-, 5SH-, 5RH-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5H-, 5DH-, 5CH-, 5BH-, 55H-, 53H-, 50H-, 10H-
Declaration Number: HE_01001_03.18
Manufacturer Specification: Food hygieneManufacturer DeclarationGerman , English -
Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H
Product Code: O5H2B-, O5H1B-, DKH-, DK5HB-, DK5G-, 5SH-, 5RH-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5DH-, 5CH-, 5BH-, 55H-, 53H-, 50H-, 10H-
Declaration Number: HE_00404_04.17
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationGerman , English -
Dosimag, Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H, Promag P
Product Code: 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5RH-, 5SH-, DDA-, DK5G-, DK5HA-, DK5HB-, DKH-, O5H1B-, O5H2B-, O5P1B-, O5P2B-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5H-, 5DH-, 5CH-, 5BH-, 55S-, 55H-, 53P-, 53H-, 50P-, 50H-, 10P-, 10H-
Declaration Number: FDA_00131_04.17FDA DeclarationGerman , English -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Declaration Number: EC_00422_03.16EU DeclarationGerman , English -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Declaration Number: EC_00410_02.16EU DeclarationGerman , English -
Dosimag OEM, Promag 10, Promag 50, Promag 53, Promag 55, Promag H
Product Code: O5H1B-, 5SH-, 5RH-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5DH-, 5CH-, 5BH-, 55H-, 53H-, 50H-, 10H-
Declaration Number: EC_00714_03.18EU DeclarationGerman , English -
Dosimag OEM, Promag H, Promag 10, Promag 50, Promag 53, Promag 55
Product Code: O5H1B-, 5H5B-, 5H1B-, 5H3B-, 50H-, 53H-, 55H-, 5H2B-, 5SH-, 5RH-, 5DH-, 5CH-, 5BH-, 10H-
Declaration Number: EC_00714_02.18EU DeclarationGerman , English -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Declaration Number: EC_00409_04.16EU DeclarationGerman , English -
Promag H
Product Code: 5H1B-, 5H3B-, 5H5B-, O5H1B-
Declaration Number: EC_00280_03.16EU DeclarationGerman , English , fr -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRussian -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Dosimag, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4B-, 5W4C-, 5W5B-, 5H2B-, 5H1B-, 5H-, 5E2B-, 5E1B-, 5D4C-, 5D4B-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H-, 5H1B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W4D-, 5W5B-, 5W8B-, 5W8C-, DDA-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 1, zone 21
Protection: Ex tb, Ex eb ia, Ex db eb, Ex ec, Ex dbExplosion ProtectionPortuguese -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, O5W3B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,DExplosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: Ex ecExplosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, O5W3B-, O5W5B-
Region/Country:
Approval Agency:Explosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,D T6...T1, I/2/A,B,C,D A,B,C,D, I/2/A,B,C,DExplosion ProtectionEnglish -
Promag W, Promag P, Promag H
Product Code: 5W5B-, 5P5B-, 5H5B-, 5P3B-, 5H3B-
Region/Country: South Africa
Approval Agency: SABS
Category: zone 1, zone 2, zone 0, zone 21,22Explosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-, O5W5B-
Region/Country: Japan
Approval Agency: CMLExplosion ProtectionJapanese -
Promag W, Promag P, Promag H
Product Code: 5W5B-, 5P5B-, 5H5B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 21
Protection: Ex d [ia], Ex tbExplosion Protection -
Promag W, Promag P, Promag H
Product Code: 5W5B-, 5P5B-, 5H5B-, 5P3B-, 5H3B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1, zone 21Explosion ProtectionChinese -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: Ex tb, Ex ec, Ex eb ia, Ex db eb, Ex dbExplosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2Explosion ProtectionChinese -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: Europe (ATEX)
Approval Agency: SIRA
Protection: Ex tb, Ex ia tb, Ex eb ia, Ex db eb, Ex dbExplosion ProtectionEnglish -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promag W, Promag P, Promag H
Product Code: 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O5W3B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8O5B-, 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-
Region/Country: Ukrain
Approval Agency: DVSZVE
Category: zone 1, zone 21Explosion Protection -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 2
Protection: Ex ec, Ex tbExplosion ProtectionPortuguese -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-, O5W5B-
Region/Country: Japan
Approval Agency: CMLExplosion ProtectionJapanese -
Promag H, Promag P, Promag W
Product Code: O5W3B-, 5W5B-, 5P5B-, 5P3B-, 5H5B-, 5W3B-, 5H3B-
Protection: Ex d e IIC T6...T1 Gb, Ex e [ia] IIC T6...T1 Gb, Ex ic IIC Gc, Ex nA IIC T6...T1 Gc, Ex nA IIC IIC Gc, Ex tb IIIC Txxx°C Db, Ex d [ia Ga] IIC IIC Db, Ex d e [ia Ga] IIC T6...T1 Gb, Ex d e [ia Ga] IIC IIC Gb, Ex tb [ia Da] IIIC T6 Db, Ex tb [ia Da] IIIC Txxx°C Db, IIIC Txxx°C DbExplosion ProtectionRussian -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1,2Explosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex d IIC T6...T1 Gb, Ex ia IIC T6...T1 Gb, Ex nA IIC T6...T1 Gc, Ex nA IIC IIC Gc, Ex tb IIIC Txxx°C Db, Ex d [ia Ga] IIC IIC Gb, Ex d e [ia Ga] IIC T6...T1 Gb, Ex d e [ia Ga] IIC IIC Gb, Ex tb [ia Da] IIIC Txxx°C Db, IIIC Txxx°C DbExplosion ProtectionRussian -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I,II,III/1/A,B,C,D,E,F,G T6...T1, I/zone 1Explosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, O5W3B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/1/A,B,C,D,E,F,GExplosion ProtectionEnglish -
Promag H
Product Code: 5H1B-, 5H3B-, 5H5B-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
Dosimag, Dosimag OEM, Promag 10, Promag 23, Promag 50, Promag 53, Promag 55, Promag H
Product Code: O5H2B-, O5H1B-, DDA-, 5SH-, 5RH-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5H-, 5DH-, 5CH-, 5BH-, 55H-, 53H-, 50H-, 23H-, 10H-
Region/Country: International
Approval Agency:Hygienic EquipmentEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: 01.01.00Fieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: PI, PROFIBUS InternationalFieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: FieldComm GroupFieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: PI, PROFIBUS InternationalFieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 01.01.01Fieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: ODVA
Software Version: 01.00.04Fieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 01.05.00Fieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: OPC Foundation
Software Version: 01.01.03Fieldbus ConformanceEnglish -
Dosimag OEM, Promag 53, Promag H, Promag P, Promag W
Product Code: 5W5B-, 5W3B-, 5P5B-, 5P3B-, 5P1B-, 5H5B-, 5H3B-, 5H1B-, 5BH-, 53W-, 53P-, 53H-
Region/Country: USA
Approval Agency: NTEP
Approval Number: NTEP 06-019MetrologyEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A_66478/1MetrologyRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRussian -
Promag H
Product Code: 5H3B-, 5H5B-
Region/Country: International
Approval Agency: BVMarineEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, 5H1B-
Region/Country: International
Approval Agency: LRMarineEnglish -
Promag H
Product Code: 5H3B-, 5H5B-
Region/Country: International
Approval Agency: DNVGLMarineEnglish -
Promag H, Promag P, Promag W
Product Code: 5H1B-, 5H3B-, 5H5B-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency:MarineEnglish -
Promag H, Promag P, Promag W
Product Code: 5H1B-, 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: ABSMarineEnglish -
Promag H
Product Code: 5H5B-
Region/Country: USAFood SafetyEnglish -
Promag H, Promag P, Promag W
Region/Country:
Heartbeat TechnologyGerman , English
Accessories / Spare parts
-
-
Nr 31 Order code 71323007
Kit power supply, 100-230VAC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323008
Kit power supply, 24VDC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323009
Kit pow.supply,100-230VAC/24VDC, Non-haz
Usage: Promag/Promass/Prosonic Flow/ t-mass 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.
-
-
-
Nr 47 Order code 71323013
Kit main elec.extender,500 dig., Non-haz
Usage: Promag/Promass/Prosonic Flow/ t-mass 500 digital, transmitter housing, electronic compartment.
-
Nr 47 Order code 71323014
Kit main elec. extender, 500 dig.,Ex
Usage: Promag/Prosonic Flow 500 digital, transmitter housing, electronic compartment.
-
-
-
Nr 36 Order code 71323015
Kit ISEM extender, 500 digital, Ex
Usage: Promag/Promass/t-mass 500 digital, Sensor connection housing.
-
-
-
Nr 33 Order code XPD0027-
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 34 Order code XPD0037-
-
-
-
Nr 37 Order code 71323010
Kit module cartridge, 300/500, Ex
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
-
-
Nr 46 Order code 71323005
Kit ISEM ribbon cable, 300/500
Usage: Promag/Promass 300/500, t-mass 300, transmitter housing.
-
Nr 46 Order code 71323006
Kit ISEM ribbon cable, 500 digital
Usage: Promag/Promass/t-mass 500 digital, sensor connection housing.
-
-
-
Nr 35 Order code XPD0038-
-
-
-
Nr 45 Order code 71323075
Kit conn.terminal option A, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 50 Order code XPD0031-
-
-
-
Nr 45 Order code 71323076
Kit conn.terminal option B, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: 2x connection terminal 2-Pol.
-
Nr 45 Order code 71327819
Kit conn.terminal option C, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323077
Kit terminal option A, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
Nr 45 Order code 71323078
Kit terminal option B, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option B = EtherNet, PROFINET. Consists of: 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
Nr 45 Order code 71327820
Kit terminal option C, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
-
-
Nr 44 Order code 71323266
Kit connection board, Promag H, 500
Usage: Sensor connection housing. Consists of: connection board, cover to connection board.
-
Nr 44 Order code 71323267
Kit connection board, Promag H, 500, Exi
Usage: Sensor connection housing. Consists of: connection board, cover to connection board.
-
-
-
Nr 20 Order code 71323016
Kit cover, sight glass, Alu,Non-haz/Exde
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag/Promass 300/500, transmitter housing Alu, Ex. Consists of: cover sight glass Alu, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323017
Kit cover,glass, Alu, -50oC,Non-haz/Exde
Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag 500, Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
Nr 20 Order code 71323020
Kit cover, sight glass, Alu, Exd
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323021
Kit cover, sight glass, Alu, -50oC, Exd
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 70 Order code 71323026
Kit cover gasket, sight glass/blind
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast. Consists of: 10x O-Ring 110.7x3.53 HNBR.
-
Nr 70 Order code 71323027
Kit cover gasket,sight glass/blind,-50oC
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Consists of: O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 22 Order code 71323032
Kit cover, electronic compart., Alu, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 HNBR.
-
Nr 22 Order code 71323033
Kit cover, electr.compart., Alu,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 74 Order code 71323036
Kit cover gasket, electronic compart.,Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Ex. Consists of: 10x O-Ring 120,2x3,53 HNBR.
-
Nr 74 Order code 71323037
Kit cover gasket,elect.compart.,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Ex. Consists of: O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 23 Order code 71323038
Kit cover, wall mount, Alu, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu, Ex, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.
-
Nr 23 Order code 71323039
Kit cover, wall mount, Alu, -50oC, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu, Ex, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 75 Order code 71323042
Kit cover gasket, wall mount, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, connection compartment. Consists of: 10x O-Ring 88,50x3,53 HNBR.
-
Nr 75 Order code 71323043
Kit cover gasket, wall mount, -50oC, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, connection compartment. Consists of: O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 20 Order code 71384170
Kit cover, alu,Promag 400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF, wire with screw lock 1,5x150.
-
Nr 20 Order code 71408508
Kit cover, polycarb., 500 digital
Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: Cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.
-
-
-
Nr 70 Order code 71278078
Kit cover gasket, alu,400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF.
-
Nr 70 Order code 71278077
Kit 10 cover gasket, polycarbonate
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.
-
-
-
Nr 24 Order code 71228796
Kit cover, remote, Alu
Usage: Promag 400(C) = generation index C, Promag 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.
-
-
-
Nr 73 Order code 71354951
Kit housing gaskets, remote, Alu
Usage: Promag 500 digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor H, O-Ring 29,87x1,78 HNBR for sensor plug.
-
-
-
Nr 24 Order code 71323053
Kit cover, remote, stainless 1.4301
Usage: Promass 500, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.
-
-
-
Nr 73 Order code 71323059
Kit housing gaskets, remote, stainless
Usage: Promag 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket EPDM for housing/sensor H, O-Ring 29,87x1,78 HNBR for sensor plug.
-
-
-
Nr 24 Order code 71185793
Kit cover,ultra compact,stainless 1.4301
Usage: Promag/Promass 100, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.
-
-
-
Nr 73 Order code 71211573
Kit hous.gaskets,ultra compact,stainless
Usage: Promag 100, Promag 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket EPDM for housing/sensor H, O-Ring 29,87x1,78 HNBR for sensor plug.
-
Nr 73 Order code 71323068
Kit housing gaskets, remote, stainless
Usage: Promag 500 with sensor H, sensor connection housing. Consists of: gasket 121,5x 61,5 for cover, O-Ring 29,87x1,78 HNBR for sensor plug.
-
-
-
Nr 71 Order code 71323069
Kit interface gaskets, Promag 300/500
Usage: transmitter housing/sensor or transmitter housing/wall mount. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface, 5x O-Ring 29,87x1,78 HNBR for for sensor plug.
-
Nr 71 Order code 71323070
Kit interface gaskets, Promag 500, -50oC
Usage: transmitter housing/wall mount. Consists of: O-Ring 88,50x3,53 FVMQ for interface, -50oC/-58oF, O-Ring 29,87x1,78 FVMQ for for sensor plug, -50oC/-58oF.
-
-
-
Nr 11 Order code 71323081
Kit protective cover option A,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71323082
Kit protective cover option B,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
-
-
Nr 13 Order code 71276494
Kit securing clamp, screw
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital. Consists of: cover clamp, screw M4x16.
-
-
-
Nr 82 Order code 71228792
Kit display protec., 400(C)/500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: display protection 1.4301, installation material.
-
-
-
Nr 87 Order code 71343504
Kit weather protection cover,500 digital
Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing. Consists of: weather protection cover 4404.
-
Nr 87 Order code 71343505
Kit weather protection cover, 300/500
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing. Consists of: weather protection cover 4404, installation material.
-
-
-
Order code 71346427
Pipe Mounting kit Transmitter 500digital
-
Order code 71346428
Pipe Mounting kit Transmitter 500
-
Order code 71351317
Kit wireless antenna extended range
Consists of: Connection cable in the transmitter, Ex cable entry for antenna, 1.5m cable, antenna, angle with union nut.
-
Order code 5X5BXX-
-
Order code DK5012-
Promag 500, sensor cable set
Connection Cable (analog and digital) between Sensor Junction Housing and Transmitter for Remote Devices of Proline 500.
-
Order code DKH-
Promag H, mounting set
A mounting set includes 2 process connections incl. screws and the corresponding seals.
-
Order code DK5G-
Promag H/Dosimag, seal set
-
Order code DK5HB-
Promag H, distance disc
The set includes 2 distance discs incl. screws and 2 seals. For dimensions refer to the technical documentation.
-
Order code DK5HM-
Promag H, wall mounting set
-
Order code DK5HW-
Promag H, weld in tool
-
Order code DK5HA-
Promag H, adapter set
Replacement of sensor Promag A or Promag H DN 25. The set includes 2 adapters and 2 seals. For dimensions refer to the technical documentation.
-
Order code DK5HR-
-
Order code XPRFID-
-
-
Predecessor