Proline Promag P 500
Electromagnetic flowmeter
High-temperature flowmeter for process applications as remote version with up to 4 I/Os
Promag P is dedicated to chemical and process applications with corrosive liquids and highest medium temperatures. With its innovative remote transmitter Promag P 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures compliance and process safety at all times.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum;
Titanium; Duplex 1.4462 (UNS S31803)
-
Quick selection
Individual configuration
-
Benefits
Diverse applications – wide variety of wetted materials
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-free – no moving parts
Full access to process and diagnostic information – numerous, freely combinable I...
-
Field of application
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
Device properties
Nominal diameter: max...
Documents / Manuals / Software
-
Proline Promag P 500
Electromagnetic flowmeter
Technical Information (TI) -
Proline Promag P 500
FOUNDATION Fieldbus
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 500
PROFIBUS DP
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 500
HART
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 500
PROFINET
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 500
PROFIBUS PA
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 500
Modbus RS485
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 500
EtherNet/IP
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 500
PROFIBUS DP
Description of Device Parameters
Electromagnetic flowmeter
Proline Promag 500
PROFIBUS DPDevice Parameter (GP) -
Proline Promag 500
Modbus RS485
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 500
PROFINET
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 500
FOUNDATION Fieldbus
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 500
EtherNet/IP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 500
HART
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 500
PROFIBUS PA
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag P
Brief Operating Instructions
Proline Promag P
Electromagnetic sensorShort Instruction (KA)10/17English -
Proline 500
PROFIBUS PA
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)08/16English -
Proline 500
Modbus RS485
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)08/16English -
Proline 500
HART
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)08/16English -
Proline Promag
Brief Operating Instructions
Proline Promag
Part 1 of 2
Electromagnetic sensorShort Instruction (KA)04/17English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with
electromagnetic sensorShort Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with
electromagnetic sensorShort Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flowmeter
Proline 500 – digital
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Conversion Kit for Promag, Promass 300 Compact Version to Promag,
Promass 500 Remote Version
Installation Instructions
Promag, Promass 300, 500
Installation Instructions (EA) -
Replacing ISEM electronics module, ISEM extender, ribbon cable
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing the S-DAT
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacement of parts for the sensor connection housing, remote version
Promag 400 Index C, Promag 500, Promag, Promass, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Replacing Small parts
Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400 Index C,
Prosonic Flow E 100, Prosonic Flow E Heat, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Weather Protection
Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing Small Parts
Promag 400 , Promag 800 Index B, Cubemass, Promag 500, Promag, Promass,
Prosonic Flow, t-mass 500-digitalInstallation Instructions (EA) -
Replacing the transmitter
Installation Instructions
Promag 500
Installation Instructions (EA) -
Replacing connection board
Installation Instructions
Promag, Promass 500
Installation Instructions (EA) -
Replacing cover, O-ring, seal housing for transmitter wall mounting and
seal housing for the sensor side
Promag, Promass 500, 500-digital, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing RJ45-M12 Adapter
Proline 300, 500-digital
Installation Instructions (EA) -
Alteration with correspondent I/O hardware for HART, Modbus
Promag, Promass 300, 500, 500-digital
Installation Instructions (EA) -
Weather Protection
Promag, Promass 300, 500, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Replacing the display module
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digital, DKX001–Installation Instructions (EA) -
Replacing the transmitter
Installation Instructions
, , Promag 500-digital
Installation Instructions (EA) -
Replacing the Display Protection
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Activating application packages, switching the I/O function, upgrading
with additional I/O hardware
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Pipe mounting set
Installation Instructions
Promag, Promass 500
Installation Instructions (EA) -
Replacing cover, O-ring cover, Interface gasket
Promag, Promass 300, 500, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Pipe mounting set
Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Alteration to Display module, to Display module with WirelessHART or
Display module with WLAN
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing transmitter Promag, Promass 500
Installation Instructions
Promag 500, Promass 500Installation Instructions (EA) -
Kit wireless antenna for extended range
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Protective Cover connection compartment
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Installing ground disks
Promag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
Installation Instructions (EA) -
Replacing the electronics
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing the terminal connection
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the Sensor
Promag, Promass, Prosonic Flow 500-digital
Installation Instructions (EA) -
Replacing transmitter Promag, Promass 500 digital
Installation Instruction
Promag 500 digital, Promass 500 digitalInstallation Instructions (EA) -
Replacing the Components for the Transmitter
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Proline Promag 500
EAC:
1Ex d e [ia Ga] IIC T6...T5 Gb X
1Ex e ia IIC T6...T1 Gb X
1Ex d [ia Ga] IIC T6...T5 Gb X
1Ex d ia IIC T6...T1 Gb X
2Ex nA nC [ic] IIC T5...T4 Gc X
2Ex nA nC IIC T5...T4 Gc X
Ex tb [ia Da] IIIC T85 °C Db XEx Safety Instructions (XA) -
Proline Promag 500
INMETRO:
Zona 2
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promag 500
ATEX:
II2G
II2D
IECEx:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 500
JPN:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 500
Cl.I, II, III Div.1 for XP
(Ex d Flameproofed version)Ex Safety Instructions (XA) -
Proline Promag 500
ATEX:
II3G
IECEx:
Zone 2Ex Safety Instructions (XA) -
Proline Promag 500
NEPSI:
Zone 2Ex Safety Instructions (XA) -
Proline Promag 500
Class I Zone 2
Class I Division 2Ex Safety Instructions (XA) -
Proline Promag 500
INMETRO:
Zona 1
Zona 2
Zona 21
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promag 500
Class I, Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 500
NEPSI:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 500
EAC:
2Ex nA ic IIC T6...T1 Gc X
2Ex nA nC [ic] IIC T5...T4 Gc X
2Ex nA nC IIC T5...T4 Gc XEx Safety Instructions (XA) -
Proline Promag 500
FOUNDATION Fieldbus
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 500
PROFIBUS DP
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
Modbus RS485
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
PROFINET
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Proline Promag 500
PROFIBUS PA
Web server
Special Documentation
Web server
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Proline Promag 500
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 500
HART
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Display modules A309/A310
Display with WLAN interface
Special Documentation (SD) -
Proline Promag 500
PROFIBUS PA
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
FOUNDATION Fieldbus
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
PROFINET
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 500
EtherNet/IP
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 500
Modbus RS485
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 500
Functional Safety Manual
Special Documentation (SD) -
Proline Promag 500
EtherNet/IP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 500
HART
OPC-UA Server application package
for IIoT and SCADA applications
Special Documentation
Special Documentation
OPC-UA Server
For IIoT and SCADA applicationsSpecial Documentation (SD) -
Proline Promag 500
Connecting the connecting cable
Special Documentation
Connecting the connecting cable
Special Documentation (SD) -
Proline Promag P 300, 500
FOUNDATION Fieldbus, PROFIBUS PA
Special Documentation
Proline Promag P 300, 500; FOUNDATION Fieldbus, PROFIBUS PA
Special Documentation (SD) -
Proline Promag 500
PROFIBUS DP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 300 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300 500 HART: 1.05.00Manufacturer Information (MI) -
Proline Promag 300 / 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300 / 500 PROFIBUS PA: 1.01.00Manufacturer Information (MI) -
Proline Promag 300 500
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promag 300 500 HART: 1.01.01Manufacturer Information (MI) -
Proline Promag 300 500
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promag 300 500 Modbus RS485: 1.01.01Manufacturer Information (MI) -
Proline Promag 300/500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300/500 PROFINET: 1.01.00Manufacturer Information (MI) -
Proline Promag 300/500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300/500 Modbus RS485: 1.05.00Manufacturer Information (MI) -
Industrial Ethernet for Proline flowmeters
The system integration of the future
Innovations (IN)12/17English -
Industrial Ethernet für Proline Durchflussmessgeräte
Die Systemintegration der Zukunft
Innovations (IN)12/17German -
Proline 300/500
La technologie de mesure de débit orientée vers l’avenir
Innovations (IN)09/18fr -
Proline 300/500
La tecnologia di misura della portata orientata al futuro
Innovations (IN)05/16Italian -
Proline 300/500
La tecnología de medición de caudal del futuro
Innovations (IN)05/16Spanish -
Proline 300/500
Technologie měření průtoku orientovaná na budoucnost
Innovations (IN)05/16Czech -
Proline 300/500
American version: The future-oriented flow measuring technology
Innovations (IN)05/16English -
流量計 Proline 300/500
未来志向の流量測定技術
Innovations (IN)03/18Japanese -
Proline 300/500
Die zukunftsweisende Durchfluss-Messtechnik
Innovations (IN)03/18German -
Proline 300/500
The future-oriented flow measuring technology
Innovations (IN)03/18English -
Promag P500
Magnetisch-induktives Durchflussmessgerät getrennte Bauform zur
bidirektionalen
Messung von Flüssigkeiten mit einer Mindestleitfähigkeit von ≥ 5 μS/cm.Tender Text06/20German -
GSD Single, GSD_EH_PA_FL_Promag300_500_0x156C_0x01_0x01, 08.08.2016 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_DP_FL_Promag_300500_0x1570_0x01_0x01, 04.06.2018 (Flow, Promag 300 500, 0x1570)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promag300500_0x843C_0x02, 10.09.2019 (Flow, Promag 300 500, 0x843C)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promag300500_0x843C_0x01_0x01, 16.11.2017 (Flow, Promag 300 500, 0x843C)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PA_FL_Promag300500_0x156C_0x02, 09.11.2018 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EIP_FL_Promag_300500_0x103C_0x01_0x01, 09.01.2020 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.3Language neutral -
EDD Single, PDM_HART_FL_Promag300_500_0x003C_0x01_0x01, 09.08.2016 (Flow, Promag 300 500, 0x113C)
HART,
PDM Version: 6.1, 8.2.1, 9.0Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, PDM_PA_FL_Promag300_500_0x156C_0x01_0x01, 09.08.2016 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PDM Version: 6.1, 8.2.1, 9.0, 9.1Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, AMS11_HART_FL_Promag300_500_0x113C_0x01_0x01, 20.08.2019 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag300_500_0x113C_0x06_0x01, 20.09.2019 (Flow, Promag 300 500, 0x113C)
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promag300_500_0x843C_0x01_0x01, 27.11.2017 (Flow, Promag 300 500, 0x843C)
PROFINET,
PDM Version: 8.2.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN-CDIE_FL_Promag300_500_0x843C_0x01_0x01, 27.11.2017 (Flow, Promag 300 500, 0x843C)
PROFINET,
PDM Version: 8.2.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FCx75_HART_FL_Promag300500_0x113B_0x01_0x01, 22.02.2017 (Flow, Promag 300 500, 0x113C)
HART, Package: Package, Variant: Variant
FC475 Version: 2.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promag300_500_0x843C_0x02_0x01, 20.09.2019 (Flow, Promag 300 500, 0x843C)
PROFINET,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag300_500_0x113C_0x06_0x01, 25.09.2020 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_FL_Promag300_500_0x113C_0x02_0x01, 22.11.2018 (Flow, Promag 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_HART_FL_Promag300_500_0x113C_0x02_0x01, 22.11.2018 (Flow, Promag 300 500, 0x113
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag300_500_0x113C_0x02_0x01, 27.11.2017 (Flow, Promag 300 500, 0x113C)
HART,
PDM Version: 8.2.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Promag300500_0x103C_0x01_0x01, 29.09.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag300_500_0x113C_0x02_0x01, 28.11.2017 (Flow, Promag 300 500, 0x113C)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag300500_0x1570_0x01_0x01, 16.07.2018 (Flow, Promag 300 500, 0x1570)
PROFIBUS DP,
PDM Version: 8.2.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promag300500_0x156C_0x02_0x01, 18.01.2019 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PDM Version: 8.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag300_500_0x113C_0x01_0x01, 20.08.2019 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 10.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag300_500_0x113C_0x06_0x01, 25.09.2020 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 11.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag300_500_0x113C_0x06_0x01, 10.09.2019 (Flow, Promag 300 500, 0x113C)
HART,
Experion Version: R500
Field Device Manager Version: R500Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag300_500_0x003C_0x01_0x01, 09.08.2016 (Flow, Promag 300 500, 0x113C)
HART,
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promag_300_500_0x103C_FF_FW1_00_zz_Dev_Rev_01, 22.10.2020 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1
Plant Resource Manager Version: R3.20Device Type Manager (DTM)1.9.0.122Language neutral -
DTM Single, Promag_300_500_0x003C_FW_1_00_zz_Dev_Rev_1, 27.10.2020 (Flow, Promag 300 500, 0x113C)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1 SP4
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.8.0.139Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_00_zz_Dev_Rev_1, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.8.0.130Language neutral -
DTM Single, Promag_300_500_HART_FW_1_06_00_Dev_Rev_06, 27.10.2020 (Flow, Promag 300 500, 0x113C)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R500
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.285Language neutral -
DTM Single, Promag_300_500_MR4_FW_1_05_zz_Dev_Rev_06, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.230Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_05_zz_Dev_Rev_06, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.230Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_05_zz_Dev_Rev_06, 04.10.2019 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.39.0.230Language neutral -
DTM Single, Promag300500_PN-CDIE_FW_1_01_zz_Dev_Rev_02, 05.11.2020 (Flow, Promag 300 500, 0x843C)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.136Language neutral -
DTM Single, Promag_300_500_5x3x-5x5x_FW_1_01_zz_Dev_Rev_02, 21.10.2020 (Flow, Promag 300 500, 0x156
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0Device Type Manager (DTM)1.12.0.161Language neutral -
DTM Single, Promag_300_500_DP_FW_1_00_zz_Dev_Rev_01, 19.10.2020 (Flow, Promag 300 500, 0x1570)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0Device Type Manager (DTM)1.11.0.65Language neutral -
DTM Single, Promag_300_500_0x156C_FW_1_00_zz_Dev_Rev_1, 21.10.2020 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.11.0.104Language neutral -
DTM Single, Promag300500_PN-CDIE_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promag 300 500, 0x843C)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.65Language neutral -
DTM Single, Promag_300_500_EIP_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Unity Pro XL Version: 11.1Device Type Manager (DTM)1.10.0.59Language neutral -
DTM Single, Promag_300_500_EIP-CDIE_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.59Language neutral -
DTM Single, Promag_300_500_HART_FW_1_01_zz_Dev_Rev_02, 27.10.2020 (Flow, Promag 300 500, 0x113C)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.10.0.223Language neutral -
DTM Single, Promag_300_500_MR4_FW_1_01_zz_Dev_Rev_02, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.207Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_01_zz_Dev_Rev_02, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.207Language neutral -
AOP Single, RS_EIP_FL_Promag300500_0x103C_0x01_0x01, 01.03.2021 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
RA RSLogix 5000 Version: V20.04and later
RA Studio 5000 Version: V21 and laterAdd On Profile (AOP)1.11.01Language neutral -
Faceplate Single, PRM_HART_FL_Promag300_500_0x003C_0x01_0x01, 08.08.2016 (Flow, Promag 300 500, 0x1
HART,
Plant Resource Manager Version: R3.20Faceplate1.00.01Language neutral -
Faceplate Single, PRM_HART_FL_Promag300_500_0x113C_0x02_0x01, 28.11.2017 (Flow, Promag 300 500, 0x1
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag300_500_0x113C_0x06_0x01, 10.09.2019 (Flow, Promag 300 500, 0x1
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.20Faceplate1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_DP, 15.05.2020 (Flow)
PROFIBUS DP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 15.05.2020 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 15.05.2020 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 15.05.2020 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_ProfiNet, 15.05.2020 (Flow)
PROFINET,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 15.05.2020 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Promag P, Promag H, Promag E, Promag 55, Promag 53, Promag 50, Promag 10, Ersatzteil, Dosimag OEM, Dosimag
Product Code: 5P5B-, 5P3B-, 5H5B-, 5H3B-, 5P1B-, 5H1B-, 53H-, 53P-, 50H-, 5P2B-, 5H2B-, 50P-, 55S-, 55H-, O5H1B-, DKH-, DK5HB-, DK5G-, 5SH-, 5RH-, 5CH-, 5BH-, 5DH-, 10H-
Declaration Number: HE_01074_01.18Manufacturer DeclarationGerman , English -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, O5P1B-, O5P2B-
Declaration Number: HE_01038_03.18
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationGerman , English -
Dosimag, Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H, Promag P
Product Code: 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5RH-, 5SH-, DDA-, DK5G-, DK5HA-, DK5HB-, DKH-, O5H1B-, O5H2B-, O5P1B-, O5P2B-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5H-, 5DH-, 5CH-, 5BH-, 55S-, 55H-, 53P-, 53H-, 50P-, 50H-, 10P-, 10H-
Declaration Number: FDA_00131_04.17FDA DeclarationGerman , English -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Declaration Number: EC_00422_03.16EU DeclarationGerman , English -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Declaration Number: EC_00410_02.16EU DeclarationGerman , English -
Promag E, Promag P, Promag W
Product Code: 5E1B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4C-, 5W5B-, O5E1B-, O5P1B-, O5P2B-
Declaration Number: EC_00064_05.15EU DeclarationGerman , English , fr -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Declaration Number: EC_00409_04.16EU DeclarationGerman , English -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: O5P1B-, 5P5B-, 5P3B-, 5P2B-, 5P1B-, 55S-, 53P-, 50P-, 10P-
Declaration Number: EC_00697_03.18EU DeclarationGerman , English -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, O5P1B-
Declaration Number: EC_00696_03.18EU DeclarationGerman , English -
Promag 10, Promag 50, Promag 51, Promag 55, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 55H-, 55S-, 5D4C-, 5E1B-, 5H2B-, 5H3B-, 5L4B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4C-, 5W8B-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H-, 5H1B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W4D-, 5W5B-, 5W8B-, 5W8C-, DDA-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Dosimag, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4B-, 5W4C-, 5W5B-, 5H2B-, 5H1B-, 5H-, 5E2B-, 5E1B-, 5D4C-, 5D4B-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRussian -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, O5W3B-, O5W5B-
Region/Country:
Approval Agency:Explosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, O5W3B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,DExplosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-, O5W5B-
Region/Country: Japan
Approval Agency: CMLExplosion ProtectionJapanese -
Promag W, Promag P, Promag H
Product Code: 5W5B-, 5P5B-, 5H5B-, 5P3B-, 5H3B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 2
Protection: Ex ec, Ex tbExplosion ProtectionPortuguese -
Promag W, Promag P, Promag H
Product Code: 5W5B-, 5P5B-, 5H5B-, 5P3B-, 5H3B-
Region/Country: South Africa
Approval Agency: SABS
Category: zone 1, zone 2, zone 0, zone 21,22Explosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-, O5W5B-
Region/Country: Japan
Approval Agency: CMLExplosion ProtectionJapanese -
Promag W, Promag P, Promag H
Product Code: 5W5B-, 5P5B-, 5H5B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 21
Protection: Ex d [ia], Ex tbExplosion Protection -
Promag H, Promag P, Promag W
Product Code: O5W3B-, 5W5B-, 5P5B-, 5P3B-, 5H5B-, 5W3B-, 5H3B-
Protection: Ex d e IIC T6...T1 Gb, Ex e [ia] IIC T6...T1 Gb, Ex ic IIC Gc, Ex nA IIC T6...T1 Gc, Ex nA IIC IIC Gc, Ex tb IIIC Txxx°C Db, Ex d [ia Ga] IIC IIC Db, Ex d e [ia Ga] IIC T6...T1 Gb, Ex d e [ia Ga] IIC IIC Gb, Ex tb [ia Da] IIIC T6 Db, Ex tb [ia Da] IIIC Txxx°C Db, IIIC Txxx°C DbExplosion ProtectionRussian -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: International (IECEx)
Approval Agency: IECEx
Protection: Ex tb, Ex ec, Ex eb ia, Ex db eb, Ex dbExplosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1,2Explosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, O5W3B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/1/A,B,C,D,E,F,GExplosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: Europe (ATEX)
Approval Agency: SIRA
Protection: Ex tb, Ex ia tb, Ex eb ia, Ex db eb, Ex dbExplosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex d IIC T6...T1 Gb, Ex ia IIC T6...T1 Gb, Ex nA IIC T6...T1 Gc, Ex nA IIC IIC Gc, Ex tb IIIC Txxx°C Db, Ex d [ia Ga] IIC IIC Gb, Ex d e [ia Ga] IIC T6...T1 Gb, Ex d e [ia Ga] IIC IIC Gb, Ex tb [ia Da] IIIC Txxx°C Db, IIIC Txxx°C DbExplosion ProtectionRussian -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promag W, Promag P, Promag H
Product Code: 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O5W3B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8O5B-, 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-
Region/Country: Ukrain
Approval Agency: DVSZVE
Category: zone 1, zone 21Explosion Protection -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,D T6...T1, I/2/A,B,C,D A,B,C,D, I/2/A,B,C,DExplosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I,II,III/1/A,B,C,D,E,F,G T6...T1, I/zone 1Explosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2Explosion ProtectionChinese -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: International (IECEx)
Approval Agency: IECEx
Protection: Ex ecExplosion ProtectionEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 1, zone 21
Protection: Ex tb, Ex eb ia, Ex db eb, Ex ec, Ex dbExplosion ProtectionPortuguese -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1, zone 21Explosion ProtectionChinese -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag L, Promag P, Promag W
Product Code: 5L4B-, 5L4C-, 5L8B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, O5P1B-, O5P2B-, O5W1B-, 10D-, 10L-, 10P-, 10W-, 50D-, 50L-, 50P-, 50W-, 51P-, 51W-, 53P-, 53W-, 5D4B-, 5D4C-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Promag H, Promag P, Promag W
Product Code: 5H5B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: OPC Foundation
Software Version: 01.01.03Fieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: ODVA
Software Version: 01.00.04Fieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 01.01.01Fieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: FieldComm GroupFieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 01.05.00Fieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: PI, PROFIBUS InternationalFieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: PI, PROFIBUS InternationalFieldbus ConformanceEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: 01.01.00Fieldbus ConformanceEnglish -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRussian -
Dosimag OEM, Promag 53, Promag H, Promag P, Promag W
Product Code: 5W5B-, 5W3B-, 5P5B-, 5P3B-, 5P1B-, 5H5B-, 5H3B-, 5H1B-, 5BH-, 53W-, 53P-, 53H-
Region/Country: USA
Approval Agency: NTEP
Approval Number: NTEP 06-019MetrologyEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A_66478/1MetrologyRussian -
Promag P, Promag W
Product Code: 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: BVMarineEnglish -
Promag H, Promag P, Promag W
Product Code: 5H1B-, 5H3B-, 5H5B-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: CCSMarineEnglish -
Promag H, Promag P, Promag W
Product Code: 5H1B-, 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Promag P, Promag W
Product Code: 5P3B-, 5P5B-, 5W3B-, 5W5B-, O5W3B-, O5W5B-
Region/Country: International
Approval Agency: DNVGLMarineEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, 5H1B-
Region/Country: International
Approval Agency: LRMarineEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: ABSMarineEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: Germany
Approval Agency: TÜV
Approval Number: TR.2065342.014.17Heartbeat TechnologyGerman , English
Accessories / Spare parts
-
-
Nr 31 Order code 71323007
Kit power supply, 100-230VAC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323008
Kit power supply, 24VDC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323009
Kit pow.supply,100-230VAC/24VDC, Non-haz
Usage: Promag/Promass/Prosonic Flow/ t-mass 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.
-
-
-
Nr 47 Order code 71323013
Kit main elec.extender,500 dig., Non-haz
Usage: Promag/Promass/Prosonic Flow/ t-mass 500 digital, transmitter housing, electronic compartment.
-
Nr 47 Order code 71323014
Kit main elec. extender, 500 dig.,Ex
Usage: Promag/Prosonic Flow 500 digital, transmitter housing, electronic compartment.
-
-
-
Nr 36 Order code 71323015
Kit ISEM extender, 500 digital, Ex
Usage: Promag/Promass/t-mass 500 digital, Sensor connection housing.
-
-
-
Nr 33 Order code XPD0027-
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 34 Order code XPD0037-
-
-
-
Nr 37 Order code 71323010
Kit module cartridge, 300/500, Ex
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
-
-
Nr 46 Order code 71323005
Kit ISEM ribbon cable, 300/500
Usage: Promag/Promass 300/500, t-mass 300, transmitter housing.
-
Nr 46 Order code 71323006
Kit ISEM ribbon cable, 500 digital
Usage: Promag/Promass/t-mass 500 digital, sensor connection housing.
-
-
-
Nr 35 Order code XPD0038-
-
-
-
Nr 45 Order code 71323075
Kit conn.terminal option A, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 50 Order code XPD0031-
-
-
-
Nr 45 Order code 71323076
Kit conn.terminal option B, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: 2x connection terminal 2-Pol.
-
Nr 45 Order code 71327819
Kit conn.terminal option C, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323077
Kit terminal option A, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
Nr 45 Order code 71323078
Kit terminal option B, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option B = EtherNet, PROFINET. Consists of: 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
Nr 45 Order code 71327820
Kit terminal option C, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
-
-
Nr 44 Order code 71323264
Kit connection board, Promag P/W, 500,Ex
Usage: Sensor connection housing. Consists of: connection board, cover to connection board.
-
-
-
Nr 20 Order code 71323016
Kit cover, sight glass, Alu,Non-haz/Exde
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag/Promass 300/500, transmitter housing Alu, Ex. Consists of: cover sight glass Alu, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323017
Kit cover,glass, Alu, -50oC,Non-haz/Exde
Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag 500, Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
Nr 20 Order code 71323020
Kit cover, sight glass, Alu, Exd
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323021
Kit cover, sight glass, Alu, -50oC, Exd
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
Nr 20 Order code 71323024
Kit cover, sight glass, cast, Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing cast, Ex. Consists of: cover sight glass cast, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323025
Kit cover, sight glass, cast, -50oC, Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing cast, Ex. Consists of: cover sight glass cast, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 70 Order code 71323026
Kit cover gasket, sight glass/blind
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast. Consists of: 10x O-Ring 110.7x3.53 HNBR.
-
Nr 70 Order code 71323027
Kit cover gasket,sight glass/blind,-50oC
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Consists of: O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 22 Order code 71323032
Kit cover, electronic compart., Alu, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 HNBR.
-
Nr 22 Order code 71323033
Kit cover, electr.compart., Alu,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
Nr 22 Order code 71323034
Kit cover, electronic compart., cast, Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing cast, Ex. Consists of: cover cast, O-Ring 120,2x3,53 HNBR.
-
Nr 22 Order code 71323035
Kit cover, electr.compart.,cast,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing cast, Ex. Consists of: cover cast, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 74 Order code 71323036
Kit cover gasket, electronic compart.,Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Ex. Consists of: 10x O-Ring 120,2x3,53 HNBR.
-
Nr 74 Order code 71323037
Kit cover gasket,elect.compart.,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Ex. Consists of: O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 23 Order code 71323038
Kit cover, wall mount, Alu, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu, Ex, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.
-
Nr 23 Order code 71323039
Kit cover, wall mount, Alu, -50oC, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu, Ex, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
Nr 23 Order code 71323040
Kit cover, wall mount, cast, Ex
Usage: Promag/Promass 500, wall mount transmitter cast, Ex, connection compartment. Consists of: cover cast, O-Ring 88,50x3,53 HNBR.
-
Nr 23 Order code 71323041
Kit cover, wall mount, cast, -50oC, Ex
Usage: Promag/Promass 500, wall mount transmitter cast, Ex, connection compartment. Consists of: cover cast, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 75 Order code 71323042
Kit cover gasket, wall mount, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, connection compartment. Consists of: 10x O-Ring 88,50x3,53 HNBR.
-
Nr 75 Order code 71323043
Kit cover gasket, wall mount, -50oC, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, connection compartment. Consists of: O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 20 Order code 71384170
Kit cover, alu,Promag 400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF, wire with screw lock 1,5x150.
-
Nr 20 Order code 71408508
Kit cover, polycarb., 500 digital
Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: Cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.
-
-
-
Nr 70 Order code 71278078
Kit cover gasket, alu,400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF.
-
Nr 70 Order code 71278077
Kit 10 cover gasket, polycarbonate
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.
-
-
-
Nr 24 Order code 71228796
Kit cover, remote, Alu
Usage: Promag 400(C) = generation index C, Promag 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.
-
-
-
Nr 73 Order code 71228798
Kit housing gaskets, remote, Alu
Usage: Promag 400(C) = generation index C, Promag 500, Promag 500 digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor L/P/W, O-Ring 29,87x1,78 HNBR for sensor plug.
-
-
-
Nr 24 Order code 71323063
Kit cover, remote, cast, Ex
Usage: Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover cast, O-Ring 120,2x3,53 HNBR.
-
-
-
Nr 73 Order code 71323067
Kit housing gaskets, remote, cast, Ex
Usage: Promag 500, Promag 500 digital, sensor connection housing. Consists of: O-Ring 120,2x3,53 HNBR for cover, O-Ring 88,50x3,53HNBR for housing/sensor O-Ring 29,87x1,78 HNBR for sensor plug.
-
-
-
Nr 71 Order code 71323069
Kit interface gaskets, Promag 300/500
Usage: transmitter housing/sensor or transmitter housing/wall mount. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface, 5x O-Ring 29,87x1,78 HNBR for for sensor plug.
-
Nr 71 Order code 71323070
Kit interface gaskets, Promag 500, -50oC
Usage: transmitter housing/wall mount. Consists of: O-Ring 88,50x3,53 FVMQ for interface, -50oC/-58oF, O-Ring 29,87x1,78 FVMQ for for sensor plug, -50oC/-58oF.
-
-
-
Nr 11 Order code 71323081
Kit protective cover option A,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71323082
Kit protective cover option B,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
-
-
Nr 13 Order code 71276494
Kit securing clamp, screw
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital. Consists of: cover clamp, screw M4x16.
-
-
-
Nr 82 Order code 71228792
Kit display protec., 400(C)/500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: display protection 1.4301, installation material.
-
-
-
Nr 87 Order code 71343504
Kit weather protection cover,500 digital
Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing. Consists of: weather protection cover 4404.
-
Nr 87 Order code 71343505
Kit weather protection cover, 300/500
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing. Consists of: weather protection cover 4404, installation material.
-
-
-
Order code 71346427
Pipe Mounting kit Transmitter 500digital
-
Order code 71346428
Pipe Mounting kit Transmitter 500
-
Order code 71351317
Kit wireless antenna extended range
Consists of: Connection cable in the transmitter, Ex cable entry for antenna, 1.5m cable, antenna, angle with union nut.
-
Order code 5X5BXX-
-
Order code DK5012-
Promag 500, sensor cable set
Connection Cable (analog and digital) between Sensor Junction Housing and Transmitter for Remote Devices of Proline 500.
-
Order code DK5GD-
Promag, grounding disc/protection disc
Includes 1 grounding disc/protection disc
-
Order code DK5GC-
-
Order code XPRFID-
-
-
Predecessor