Proline t-mass T 150
Thermal mass flowmeter
The flowmeter for reliable and easy monitoring of liquids
The t-mass T 150 is the first thermal mass device from Endress+Hauser for measuring liquids. t-mass T 150 is designed chiefly for water applications. As it measures independently of the electrical conductivity of a fluid and can be used in a variety of water-based and non-water-based liquids for the purpose of monitoring and trending. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Flow: ±5 % o.f.s.
-
Measuring range
226 to 14 100 000 l/h (60 to 3 730 000 gal/h)
(under reference conditions) -
Medium temperature range
–20 to +100 °C (–4 to +212 °F)
-
Max. process pressure
PN 40
-
Wetted materials
Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection:
‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Tri‐Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L)
-
Quick selection
Individual configuration
-
Benefits
Dedicated to the monitoring of conductive and non-conductive liquids
High process safety – high repeatability and linearity due to integrated temperature compensation
Cost-effective measurement – easy installation, negligible pressure loss and maintenance...
-
Field of application
Measuring principle is characterized by a high operable flow range and direct mass flow measurement
Dedicated to the monitoring of conductive and non-conductive liquids.
Device properties
Insertion version for nominal diameter DN 40 to 1000 (1 1/2 to 40")
Sensor in standard or hygienic version
SIP cleaning possible up...
Documents / Manuals / Software
-
Proline t-mass T 150
Technical Information
Thermal mass flowmeter
Technical Information (TI) -
Proline t-mass T 150
HART
Operating Instructions
Thermal mass flowmeter
Operating Instruction (BA) -
Proline t-mass T 150
HART
Description of Device Parameters
Thermal Mass Flowmeter
Device Parameter (GP) -
Proline t-mass T 150
Brief Operating Instructions
Thermal mass flowmeter
Short Instruction (KA)12/13English -
Safety chain
Installation Instructions
t-mass T 150
Installation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Replacing the display module
Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50Installation Instructions (EA) -
Replacing small parts
Installation Instructions
t-mass A, B, T 150
Installation Instructions (EA) -
Mounting the Weather Protection
Installation Instructions
t-mass T 150
Installation Instructions (EA) -
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Installation Instructions (EA) -
Cold tap, atmospheric pressure
t-mass 65I, t-mass B 150, t-mass T 150, t-mass I 300, t-mass I
500-digitalInstallation Instructions (EA) -
Proline t-mass 150
ATEX: II3G Ex nA IIC T4…T1
IECEx: Zone 2 Ex nA IIC T4…T1
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Yardımcı işletmelerde akış ölçümü
Basınçlı hava, gaz, buhar ve su için özel enerji yönetimi çözümleri
Competence Brochure (CP)07/14Turkish -
Mesure de débit dans les circuits auxiliaires
Solutions sur mesure pour la gestion de l'énergie : air comprimé, gaz,
vapeur et eauCompetence Brochure (CP)07/14fr -
Proline t-mass T 150
For simple liquid flow monitoring
Innovations (IN)12/13English -
Proline t-mass T 150
Für die einfache Durchflusskontrolle von Flüssigkeiten
Innovations (IN)12/13German -
Proline t-mass T 150
最便捷的液体流量和温度监测
Innovations (IN)12/13Chinese -
T-mass T150
Überwachung von Durchfluss nach dem Thermischen-Prinzip als Kompaktgerät
in
Einsteckausführung mit HilfsenergieTender Text06/20German -
EDD Single, PDM_HART_FL_t-mass150LT_0x0068_0x01_0x01, 01.10.2014 (Flow, t-mass 150, 0x0068)
HART,
PDM Version: 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_t-mass150LT_0x0068_0x01_0x01, 05.08.2015 (Flow, t-mass 150)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_t-mass150LT_0x0068_0x01_0x01, 21.08.2019 (Flow, t-mass 150, 0x0068)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_t-mass150LT_0x0068_0x01_0x01, 21.08.2019 (Flow, t-mass 150, 0x0068)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, t-mass150LT150_6xAB_HART_FW1_00_zz_Dev_Rev_1, 26.10.2020 (Flow, t-mass 150, 0x0068)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.2.0.42Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Single, PRM_HART_FL_t-mass150_0x0068_0x01_0x01, 01.10.2014 (Flow, t-mass 150, 0x0068)
HART,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
t-mass A, t-mass B, t-mass T
Product Code: 6AAB-, 6BAB-, 6TAB-, O6AAB-
Declaration Number: EC_00296_02.16EU DeclarationGerman , English , fr -
t-mass A, t-mass B, t-mass T
Product Code: 6AAB-, 6BAB-, 6TAB-
Declaration Number: EC_00295_01.16EU DeclarationGerman , English , fr -
t-mass T, Prowirl R, Prowirl O, Prowirl F, T-MASS I, T-MASS F, t-mass B, t-mass A, t-mass, Prowirl D, PROSONIC FLOW P, Prosonic Flow G, PROSONIC FLOW E, Prosonic Flow 93, Prosonic Flow B, Prosonic Flow 92, Prosonic Flow 91, PICOMAG, Magphant, Dosimass, Promass 40, Promag D
Product Code: 92F-, ODMA-, 7R2B-, 7F2B-, 93P-, 93W-, 7O2B-, 7D2B-, 7O2C-, 7F2C-, 7R2C-, 65I-, 93C-, 7D2C-, 65F-, 93TA1-, 9B2B-, 9E1B-, 9EHB-, 9G3B-, 9G5B-, 9P5B-, DMA-, DTI200-, DTT31-, DTT35-, DTT35L-, DTT31L-, 91W-, 8E-, 6TAB-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 5D4C-, 40E-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EACE N RU-D.CH.AD07.B.02246/20MiscellaneousRussian -
t-mass A, t-mass B, t-mass L, t-mass T
Product Code: 6AAB-, 6BAB-, 6TAB-, 6LAB-, O6AAB-, O6BAB-, O6LAB-, O6TAB-
Region/Country: International (IECEx)
Approval Agency: CSAExplosion ProtectionEnglish -
t-mass A, t-mass B, t-mass L, t-mass T
Product Code: 6AAB-, 6BAB-, 6TAB-, 6LAB-, O6AAB-, O6BAB-, O6LAB-, O6TAB-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D/Explosion ProtectionEnglish -
t-mass T
Product Code: 6TAB-
Region/Country: International
Approval Agency:Hygienic EquipmentEnglish -
t-mass L, t-mass T
Product Code: 6LAB-, 6TAB-
Region/Country: International
Approval Agency: FieldComm GroupFieldbus ConformanceEnglish
Accessories / Spare parts
-
-
Nr 37 Order code 71158893
Kit 10 terminal block, 8-pin,t-mass 150
-
-
-
Nr 30 Order code XPD0022-
-
-
-
Nr 40 Order code XPD0024-
Display module, SD02, push buttons
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.
-
-
-
Nr 20 Order code 71158894
Kit cover Alu, sight glass, gasket
Usage: t-mass 150. Material: Cover Aluminium, coated. O-Ring 88,50x3,53 NBR,PTFE coated.
-
Nr 20 Order code 71158895
Kit cover Alu, blind version, gasket
Usage: t-mass 150. Material: Cover Aluminium, coated. O-Ring 88,50x3,53 NBR,PTFE coated.
-
-
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 71115505
Kit 10 ext. M20x1,5/G 1/2" (plug brass)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 71115509
Kit 10 ext. M20x1,5/NPT1/2"(plug brass)
-
Nr 15 Order code 71240315
-
Nr 15 Order code 71240316
-
-
-
Nr 65 Order code 71158896
Kit housing gaskets, t-mass 150
Consists of: O-Ring 88,50x3,53 NBR, PTFE coated, cover electronic compartment. O-Ring 36,10x3,53 HNBR, housing/sensor.
-
-
-
Nr 19 Order code 71158897
Kit housing parts, t-mass 150
Consists of: Filter plug, Brass Nickel. Pressure compensation filter, PTFE. Hexagon socket set screw M8x12 A2.
-
-
-
Nr 63 Order code 71158898
Kit gasket ring,HNBR,3/4",t-mass B/T 150
Consists of: Gasket ring 35,0/26,7x2,0, HNBR, 316.
-
Nr 63 Order code 71158900
Kit gasket ring,EPDM,3/4",t-mass B/T 150
Consists of: Gasket ring 35,0/26,7x2,0, EPDM, 316.
-
-
-
Order code 71240321
Kit Safety chain, t-mass T 150
Usage: For pressure >= 4,5 bar (65,27 psi) and PEEK-ferrule.
-
Order code 71240320
Kit weather protec.cover, t-mass 150
Consists of: Weather protective cover, installation material.
-
Order code DK6MB-
-
Order code DK6002-
t-mass T 150, mounting kit
For mounting the insertion version in a process pipe.
-
Order code DK6HT-
Hot tap, process pressure, 65I/150
Usage: t-mass 65I, 6BAB, 6TAB. For insertion version. For mounting and extracting the device under operating conditions.
-
Order code DK6ML-
Cold tap, atmospheric pressure, t-mass
Usage: t-mass 65I, 6BAB, 6TAB, 6I3B, 6I5B. For insertion version. For mounting and extracting the device at atmospheric pressure. Min. insertion length: 335mm (13in).
-
Order code XPRFID-
-
-
Predecessor