Specs at a glance
-
Input
1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional -
Output / communication
2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet -
Ingres protection
IP66 / IP 67
Field of application
The Liquiline CM444 transmitter allows you to connect up to 4 Memosens sensors of your choice from over 12 measurement parameters. It offers automatic sensor recognition, flexible expandability, and standardized spare parts with all other devices of the Liquiline platform. With its inputs, outputs, controllers, and math modules, you can even control cleaning systems or dosing pumps. Heartbeat Technology helps you find the ideal balance between measuring point availability and maintenance costs.
Liquiline CM444 is suitable for all industries and their utilities, such as:
Food & Beverages
Life Sciences
Power & Energy
Water & Wastewater
Chemicals
Marine
It features the following communication protocols and interfaces:
0/4...20 mA
HART
PROFIBUS DP
Modbus RS485/RTU
Modbus TCP
EtherNet/IP
PROFINET
Webserver
The transmitter can be extended with a module whose explosion protection approvals, such as IECEx, ATEX, and CSA, allow the connection of sensors installed in hazardous areas.
Benefits
Clever simplicity:
One controller for all parameters and applications, intuitive user interface, automatic sensor recognition, hot plug & play with pre-calibrated Memosens sensors.Highest flexibility:
Universal modules for all parameters minimize spare part stock and allow for easy 1-click extension to up to 8 channels at any time.Seamless system integration:
Unique portfolio of communication standards suits every distributed control system (DCS).Simple and safe commissioning:
Saving configuration on SD card enables fast set-up on duplicate installations.Process control from a distance:
Integrated web server that allows the operator to remotely view diagnostic data, perform configurations, or access device parameters in any web browser - even via Smartphone.Higher availability, lower costs:
Heartbeat Technology enables status-oriented maintenance and easy verification of the entire measuring point and helps to carry out optimization measures.
Videos
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
Liquiline CM442/CM444/CM448
English version - 05/2020
Multiparameter transmitter with a maximum of eight measuring channels based on digital Memosens technology
EN 10/08/202204/07/202203/05/202211/05/202028/02/2019Language:
English
Version:
11/05/2020
File size:
7.1 MB
File name:
TI00444CEN_2319.pdf
-
-
-
Technical Information (TI)
Liquiline CM442/CM444/CM448
Multiparameter transmitter with a maximum of eight measuring channels based on digital Memosens technology
EN 10/08/202204/07/202203/05/202211/05/202028/02/2019Language:
English
Version:
10/08/2022
File size:
5.9 MB
File name:
TI00444CEN_2622-00.pdf
-
-
-
Operating Instruction (BA)
Memosens
Sensor inputs with Memosens protocol
EN 30/05/202228/02/2019Language:
English
Version:
30/05/2022
File size:
3.3 MB
File name:
BA01245CEN_0822-00.pdf
-
-
-
Operating Instruction (BA)
Operating Instructions
Universal four-wire multichannel controller
EN 15/12/201115/12/2010Language:
English
Version:
15/12/2011
File size:
1.1 MB
File name:
BA00451CEN_1411.pdf
-
-
-
Operating Instruction (BA)
Operating Instructions CM44x
Maintenance and diagnostics
EN 01/08/201215/12/201115/12/201001/04/2010Language:
English
Version:
01/08/2012
File size:
2.5 MB
File name:
BA00445CEN_1512.pdf
-
-
-
Operating Instruction (BA)
Operating Instructions CM44x
Operation and settings
EN 25/03/201301/08/201215/12/201115/12/201001/04/2010Language:
English
Version:
25/03/2013
File size:
6.4 MB
File name:
BA00450CEN_1613.pdf
-
-
-
Operating Instruction (BA)
Operating Instructions
Communication via the HART protocol
EN 27/06/201315/09/2011Language:
English
Version:
27/06/2013
File size:
1.9 MB
File name:
BA00486CEN_0213.pdf
-
-
-
Operating Instruction (BA)
Liquiline CM442/CM444/CM448
Universal four-wire multichannel controller Field device
EN 10/08/202204/07/202208/10/202106/05/202127/01/2020Language:
English
Version:
10/08/2022
File size:
8.8 MB
File name:
BA00444CEN_3022-00.pdf
-
-
-
Short Instruction (KA)
Liquiline CM442/CM444/CM448
Universal four-wire multichannel controller
EN 12/08/202208/10/202106/05/202130/11/201930/05/2018Language:
English
Version:
12/08/2022
File size:
3.4 MB
File name:
KA01159CEN_0922-00.pdf
-
-
-
Installation Instructions (EA)
SD card kit
32 GB, industrial flash drive
EN 23/03/2021Language:
English
Version:
23/03/2021
File size:
506.7 KB
File name:
EA01354CEN_0121.pdf
-
-
-
Installation Instructions (EA)
Kit Mastbefestigung Post mounting kit 71096920 Installation Instructions
Kit Mastbefestigung
EN 28/02/201711/06/201431/12/2011Language:
English
Version:
28/02/2017
File size:
659.1 KB
File name:
EA00010CA2_0317.pdf
-
-
-
Installation Instructions (EA)
Kit CM44x / CSXxx / CA80xx Kit Module 485/ETH Installation Instructions
For Ethernet configuration, PROFIBUS, Modbus
EN 22/08/201722/06/201531/01/201431/12/2011Language:
English
Version:
22/08/2017
File size:
2.1 MB
File name:
EA00009CA2_0417.pdf
-
-
-
Installation Instructions (EA)
Einbauanleitung/ Installation Instructions Kit Module/Modules
Für erweiterte Funktionalität For extended functionality
EN 07/07/201425/03/201331/12/2011Language:
English
Version:
07/07/2014
File size:
2.4 MB
File name:
EA00008CA2_0314.pdf
-
-
-
Installation Instructions (EA)
Kit CM44x/CSXxx/CA80XX
Module 485MB or 485DP For Ethernet configuration,PROFIBUS DP, Modbus RS485
EN 28/11/2022Language:
English
Version:
28/11/2022
File size:
1.8 MB
File name:
EA01447CEN_0122-00.pdf
-
-
-
Installation Instructions (EA)
Kit 2DS Ex-i module for CM44x(R) / CM44P
Replacement / repair of the 2DS Ex-i module for CM44x(R) / CM44P
EN 04/07/2022Language:
English
Version:
04/07/2022
File size:
3.5 MB
File name:
EA01413CEN_0122-00.pdf
-
-
-
Installation Instructions (EA)
SD card kit
Industrial flash drive, 1 GB With firmware, no. 71127100 Without firmware, no. 71110815
EN 23/03/202109/10/202020/03/201725/06/201401/07/2012Language:
English
Version:
23/03/2021
File size:
506.9 KB
File name:
EA00011CEN_0621.pdf
-
-
-
Ex Safety Instruction (XA)
Liquiline CM442, CM444, CM448, CM442R, CM444R, CM448R, CM44P
Supplement to: BA00444C, BA01225C, BA01570C, BA01954C Safety instructions for electrical apparatus in explosion-hazardous areas for ATEX, IECEx
EN 27/01/202210/06/2021Language:
English
Version:
27/01/2022
File size:
1.5 MB
File name:
XA02419CEN_0221-00.pdf
-
-
-
Ex Safety Instruction (XA)
XA Liquiline CM442, CM444, CM448, CM442R, CM444R, CM448R, CM44P
Universal four-wire multichannel controller CSA CL I, DIV 2, GP A-D T4A
Language:
English
Version:
05/05/2023
File size:
8.9 MB
File name:
XA02420CEN_0123-00.pdf
-
-
-
Ex Safety Instruction (XA)
Liquiline CM442, CM444, CM448, CM442R, CM444R, CM448R, CM44P
UK Ex II (1)G [Ex ia Ga] IIC Safety instructions for electrical apparatus in explosion-hazardous areas
Language:
English
Version:
22/03/2022
File size:
1.5 MB
File name:
XA02762CEN_0121-00.pdf
-
-
-
Special Documentation (SD)
Special Documentation Liquiline 4-wire Platform
Modbus Guideline
EN 31/05/202224/01/202027/11/201914/07/201722/07/2014Language:
English
Version:
31/05/2022
File size:
1.8 MB
File name:
SD01189CEN_07.22.pdf
-
-
-
Special Documentation (SD)
List of Tested Devices and Versions SE03 Schneider Electric Modicon M580and EtherNet/IP plus PROFIBUS PA for Mining Industry
This document lists all relevant components and devices with versions as used for testing of the Reference Topology SE03. All content of this document is jointly developed, reviewed and approved by Schneider Electric and Endress+Hauser as a common deliverable of Open Integration.
Language:
English
Version:
14/04/2021
File size:
312 KB
File name:
SD02681SEN_0120.pdf
-