Proline Promag 10E
Electromagnetic flowmeter
The economical flowmeter with a highly cost-effective transmitter
Promag E is a streamlined sensor for basic chemical applications. It is the most economical solution for our chemical customers. Combined with the Promag 10 transmitter for basic applications and direct integration, Promag 10E offers accurate measurement of liquids for a wide range of applications. It will be the preferred solution for customers aiming for minimized cost of ownership. Promag 10E is available as compact or remote version.
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
This product is not available in this market.
-
Specs at a glance
-
Max. measurement error
Volume flow: ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
-
Medium temperature range
–10 to +110 °C (+14 to +230 °F)
-
Max. process pressure
PN 40, Class 150, 20K
-
Wetted materials
Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
-
Quick selection
Individual configuration
-
Benefits
Cost-effective sensor – ideal solution for basic requirements
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-free – no moving parts
Cost-effective – designed for easily applications and direct integration
...
-
Field of application
The measuring principle is virtually independent of pressure, density, temperature and viscosity
Fully suitable for basic applications in the chemical and process industry
Device properties
Nominal diameter: max. DN 600 (24")
All common process...
Documents / Manuals / Software
-
Proline Promag 10E
Technical Information
Electromagnetic flowmeter
Technical Information (TI) -
Proline Promag 10
HART
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 10
Brief Operating Instructions
Electromagnetic flowmeter
Short Instruction (KA)11/17English -
Replacing cover and O-ring
Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73Installation Instructions (EA) -
Replacing Sensor parts remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, Cubemass 8CN,
CNGmass 8DFInstallation Instructions (EA) -
Replacing the transmitter
Installation Instructions
Promag 10, 23, 50, 53, 55
Installation Instructions (EA) -
Installing ground disks
Promag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
Installation Instructions (EA) -
Interface parts
Installation Instructions
Promag 10, 23, 50, 51, 53, 55, 400, 800
Installation Instructions (EA) -
Replacing transmitter parts
Installation Instructions
Promag 10, Prosonic Flow 91 W
Installation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Promag 10, 23, 50, 51, 53, 55
Information on the PED
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag E 100
Proline Promag 10E / 50E / 53E
Flow measurement for basic applications in the chemical and process
industryInnovations (IN)08/14English -
Proline Promag E 100
Proline Promag 10E / 50E / 53E
Durchflussmessung für Basisanwendungen in der Chemie- und
ProzessindustrieInnovations (IN)08/14German -
DTM Single, Promag_10_V1_03_00, 23.10.2020 (Flow, Promag, 0x0045)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Promag 10
Product Code: 10D-, 10E-, 10H-, 10L-, 10P-, 10W-
Declaration Number: EC_00289_01.16EU DeclarationGerman , English , fr -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 50W-, 50P-, 50E-, 10W-, 10P-, 10E-, 55S-, 53W-, 53P-, 53E-, 51W-, 51P-
Declaration Number: EC_00054_04.15EU DeclarationGerman , English , fr -
Promag 10, Promag 50, Promag 51, Promag 55, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 55H-, 55S-, 5D4C-, 5E1B-, 5H2B-, 5H3B-, 5L4B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4C-, 5W8B-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 53L-, 53P-, 53W-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H1B-, 5H2B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5W4B-, 5W4C-, 5W8B-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H-, 5H1B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W4D-, 5W5B-, 5W8B-, 5W8C-, DDA-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRussian -
Dosimag, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4B-, 5W4C-, 5W5B-, 5H2B-, 5H1B-, 5H-, 5E2B-, 5E1B-, 5D4C-, 5D4B-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag 10
Product Code: 10D-, 10P-, 10H-, 10W-, 10L-, 10E-
Region/Country: Canada
Approval Agency: CSA
Category: I/2/A,B,C,D/, II,III/1/E,F,G/T6...T1
Protection: DIP, NIExplosion ProtectionEnglish -
Promag 10
Product Code: 10D-, 10E-, 10H-, 10L-, 10P-, 10W-
Region/Country: USA
Approval Agency: FM
Category: I/2/A,B,C,D/T6...T1, II,III/1/E,F,G/T6...T1
Protection: DIP, NIExplosion ProtectionEnglish -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRussian -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 53H-, 53W-, 53P-, 50H-, 50P-, 50W-, 55S-, 55H-, 50D-, 53L-, 53E-, 50L-, 51W-, 51P-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A № 56810_1MetrologyRussian
Accessories / Spare parts
-
-
Nr A Order code 50104751
Kit Main-PCB Promag 10, 85-250VAC
-
Nr A Order code 50104752
Kit Main-PCB Promag 10,20-28VAC/11-40VDC
-
Nr A Order code 71098237
-
Nr A Order code 71098239
-
-
-
Nr 3 Order code 50104749
Kit 10 fuses 1.0 A/250 slow
-
Nr 3 Order code 50104750
Kit 10 fuses 1.6 A/250 slow
-
-
-
Nr B Order code 50104745
Kit display 10/91W with keyboard
-
-
-
Nr C Order code 50104754
Kit connec. board PMAG10 FS elect
-
Nr C Order code 71098240
-
-
-
Nr D Order code 50098018
-
Nr D Order code 71039497
Kit connection board D/E/L/P/S/W FS HE
Usage: 10/50/53/55 HE = harsh environment
-
-
-
Nr 1 Order code 50108138
Kit Terminal Block 10/1YH/91W
-
-
-
Nr 13 Order code 50094038
-
-
-
Nr 9 Order code 50094038
-
-
-
Nr 5 Order code 50104746
Kit cover 10/91W with window
-
-
-
Nr 6 Order code 50104747
Kit cover 10/1YH/91W blind version
-
-
-
Nr 10 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 10 Order code 50096840
Kit 10 cable glands M20x1,5
-
Nr 10 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 10 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
-
-
Nr 4 Order code 50104748
Kit PCB/Display carrier 10/91W
-
-
-
Nr 7 Order code 50104753
Kit housing gaskets Promag10/1YH housing
-
-
-
Nr 8 Order code 50097147
-
-
-
Nr 2 Order code 50099102
Kit Bushing to field/SS-housing
-
-
-
Nr 15 Order code 50098019
Kit parts housing FS Stnd/HT
Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W
-
-
-
Nr 12 Order code 50098020
Kit parts housing compact Stnd/HT
Usage: 10/23/50/51/53/55 Sensor: D/E/H/L/P/S/W
-
-
-
Nr 14 Order code 50098023
Kit housing gasket FS Stnd/HT
Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W
-
-
-
Nr 11 Order code 50098024
Kit housing gasket compact Stnd/HT
Usage: 10/23/50/51/53/55 Sensor: D/E/L/P/S/W
-
-
-
Order code 10XXX-
Promag 10, transmitter
-
Order code DK5CA-
Promag, cable remote version
10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable
-
Order code DK5WM-
-
Order code DK5GC-
-
Order code DK5GD-
Promag, grounding disc/protection disc
Includes 1 grounding disc/protection disc
-
Order code FXA193-
Serviceinterface FXA193
The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.
-