Specs at a glance
Accuracy
(Pt100) <= 0,1 K (Pt100) <= 0,18 °F
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers digital converted signals from RTD and TC sensors, it also transfers resistance and voltage signals using PROFIBUS® PA communication. High measurement point availability by means of sensor monitoring functions. Diagnostics information according to NAMUR NE 107. Optimization of the measurement accuracy by sensor-transmitter matching.
2 input channels and PROFIBUS® PA protocol for the conversion of input signals into digital output signals
The device stands out due to signal reliability, long-term stability, high precision and advanced diagnostics (important in critical processes)
For the highest level of safety, availability and risk reduction
Installation in flat-face terminal head as per DIN EN 50446
Optional installation in field housings even for use in Ex d areas - with mounting brackets for wall or pipe mounting
Benefits
Easy and standardized communication via PROFIBUS® PA Profile 3.02
Meets the EMC requirements as per NAMUR NE 21 and the recommendations of NE 89 with regard to temperature transmitters with digital signal processing
Straightforward design of measuring points in Ex-areas through FISCO/FNICO conformity in accordance with IEC 600079-27
Safe operation in hazardous areas thanks to international approvals such as FM IS, NI, CSA IS, NI as well as ATEX Ex ia, Ex nA (Ex nL)
High accuracy through sensor-transmitter matching
Reliable operation with sensor monitoring and device hardware fault recognition
Rapid no-tools wiring due to optional spring terminal technology
Extended selection
High-end products
Highly functional and convenient
Technical excellence
Simplicity
©Endress+Hauser
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Loading alternative products
Success stories
Tube skin temperature measurement
How thermometers can detect pipe overheating, lead to significant energy savings and increase process efficiency and product quality
Read the full story
Medical autoclaves
New sensor technology automates recalibrations to reduce risk in batch sterilization. Learn More!
Read the full story
Auxiliary power supply
9...32 V DC (PROFIBUS PA) 9...17,5 V DC (FISCO/FNICO)
Accuracy
(Pt100) <= 0,1 K (Pt100) <= 0,18 °F
Certification
ATEX II3G Ex ic IIC T6 Gc ATEX II2D Ex tb IIIC Db ATEX II1G Ex ia IIC T4/T5/T6 ATEX II3G Ex nA IIC T6 Gc ATEX II3D Ex tc IIIC Dc ATEX II1G Ex ia IIC T6 Ga, II3D ATEX II3G Ex nA IIC T6 Gc, II3D ATEX II2G Ex d T6, II2D Ex tb IIIC FM+CSA IS, NI I/1+2/ABCD CSA C/US General Purpose FM IS, NI I/1+2/ABCD CSA IS, NI I/1+2/ABCD CSA XP, NI, DIP I, II, III/1+2/A-G NEPSI Ex ia IIC T4/T5/T6 TIIS Ex ia IIC T6 NEPSI Ex nA IIC T4/T5/T6 IECEx Ex ia IIC T4/T5/T6 FM XP, NI, DIP I, II, III/1+2/A-G EAC Ex ia IIC T6 Ga EAC Ex d IIC T6 Gb IECEx Ex tb IIIC Db IECEx Ex d T6 Gb, Ex tb IIIC Db INMETRO Ex ia [ia Ga] IIC T6 Gb INMETRO Ex d T6 Gb, Ex tb IIIC Db NEPSI Ex d IIC T6 Gb UK II2D Ex tb IIIC Db UK II3D Ex tc IIIC Dc UK II1G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db ATEX IECEx II1G Ex ia IIC T6 Ga
Most downloaded
iTEMP TMT84
English version - 05/2022
Dual-input temperature transmitter with PROFIBUS<sup>®</sup>
PA protocol
EN
DE ES FR IT JA PT RU ZH
04/05/2022
31/03/2020
07/03/2017
13/09/2012
01/08/2011
Language:
English
Version:
04/05/2022
File size:
2.3 MB
File name:
BA00257REN_0622-00.pdf
iTEMP TMT84
English version - 11/2021
Dual-input temperature transmitter
EN
DE ES FR IT JA PT RU ZH
20/11/2021
31/03/2020
06/02/2017
28/06/2012
21/06/2012
Language:
English
Version:
20/11/2021
File size:
1.5 MB
File name:
TI00138REN_0721-00.pdf
84 documents
Dual-input temperature transmitter
EN
German Spanish French Italian Japanese Portuguese Russian Chinese
20/11/2021
31/03/2020
06/02/2017
28/06/2012
21/06/2012
Language:
English
Version:
20/11/2021
File size:
1.5 MB
File name:
TI00138REN_0721-00.pdf
Dual-input temperature transmitter with PROFIBUS<sup>®</sup> PA protocol
EN
German Spanish French Italian Japanese Portuguese Russian Chinese
04/05/2022
31/03/2020
07/03/2017
13/09/2012
01/08/2011
Language:
English
Version:
04/05/2022
File size:
2.3 MB
File name:
BA00257REN_0622-00.pdf
TID10
Operating Instructions
Pluggable display for head transmitters (TMT8x)
EN
German French Italian Russian
01/03/2013
01/05/2008
01/04/2008
Language:
English
Version:
01/03/2013
File size:
606 KB
File name:
BA00262rc4_1313.pdf
Dual-input temperature transmitter
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Indonesian Italian Japanese Korean Lithuanian Latvian Dutch Norwegian Polish Portuguese Romanian Russian Slovak Slovenian Swedish Thai Turkish Chinese
15/03/2020
18/03/2016
29/10/2014
07/11/2011
01/07/2008
Language:
English
Version:
15/03/2020
File size:
1.2 MB
File name:
KA00258REN_0420.pdf
XA iTEMP TMT71, TMT72, TMT82, TMT84, TMT85, TMT86, TMT182B
ATEX: Ex ia IIIC Txxx °C Dc, Ex tc IIIC Txxx °C Dc Ex tc IIIC Txxx °C Dc, Ex tc IIIC Dc Ex nA IIC T6 Gc, Ex ec IIC T6 Gc Ex nA IIC Gc, Ex ec IIC Gc
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Italian Lithuanian Latvian Dutch Polish Portuguese Romanian Slovak Slovenian Swedish
17/07/2023
14/11/2022
15/08/2022
19/11/2018
23/03/2016
Language:
English
Version:
17/07/2023
File size:
445.5 KB
File name:
XA01006TEN_0823-00.pdf
ATEX: II1G Ex ia IIC T6…T4 Ga IECEx: Ex ia IIC T6…T4 Ga
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Italian Lithuanian Latvian Dutch Polish Portuguese Romanian Slovak Slovenian Swedish
24/11/2021
03/05/2018
20/05/2016
08/05/2015
30/01/2015
Language:
English
Version:
24/11/2021
File size:
719.7 KB
File name:
XA00069REN_0521.pdf
PROFIBUS PA®/FOUNDATION Fieldbus™ FM: Control Drawing XP, NI, DIP 340200113
Language:
English
Version:
08/06/2011
File size:
106.2 KB
File name:
340200113.pdf
PROFIBUS PA®/FOUNDATION Fieldbus™ CSA: Control Drawing XP, NI, DIP 340200114
Language:
English
Version:
08/06/2011
File size:
101 KB
File name:
340200114.pdf
iTEMP TMT82, TMT84, TMT85
PROFIBUS®, FOUNDATION Fieldbus™ ATEX, IECEx: Ex ia [ia Ga] IIC T6 Gb Safety instructions for electrical apparatus in explosion-hazardous areas
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Italian Korean Lithuanian Latvian Dutch Polish Portuguese Romanian Slovak Slovenian Swedish
20/06/2022
11/11/2020
07/11/2018
20/06/2016
23/01/2012
Language:
English
Version:
20/06/2022
File size:
400.4 KB
File name:
XA01012TEN_0522-00.pdf
XA iTEMP TMT82, TMT84, TMT85
HART®, PROFIBUS®, FOUNDATION Fieldbus™ Ex ia [ia Ga] IIC T4...T6 Gb
EN
Chinese
27/09/2023
12/09/2022
Language:
English
Version:
27/09/2023
File size:
396.2 KB
File name:
XA02917TEN_0223-00.pdf
iTEMP TMT84, TMT85,
OTMT84, OTMT85
Safety instructions ATEX: II1G Ex ia IIC T6…T4 Ga IECEx: Ex ia IIC T6…T4 Ga
Language:
English
Version:
22/01/2021
File size:
721.2 KB
File name:
XA02364TEN_0121.pdf
XA iTEMP TMT71, TMT72, TMT82, TMT84, TMT85, TMT86
ATEX: Ex ic IIC T6 Gc
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Italian Lithuanian Latvian Dutch Polish Portuguese Romanian Slovak Slovenian Swedish
18/07/2023
28/02/2023
20/08/2020
30/11/2019
23/11/2018
Language:
English
Version:
18/07/2023
File size:
449.8 KB
File name:
XA01155TEN_0723-00.pdf
temperature transmitter
iTEMP TMT82, TMT84, TMT85
EAC Ex Safety Instructions
EAC Ex 0Ex ia IIC T6...T4 Ga X 1Ex ib [ia Ga] IIC T6...T4 Gb X 1Ex d IIC T6...T4 Ga X
EN
Russian
02/03/2020
05/04/2016
Language:
English
Version:
02/03/2020
File size:
214.1 KB
File name:
XA01422T09EN_0220.pdf
XA iTEMP TMT84, iTEMP TMT85
PROFIBUS®, FOUNDATION Fieldbus™ Ex ia IIC T4...T6 Ga
EN
Chinese
15/01/2024
18/09/2023
Language:
English
Version:
15/01/2024
File size:
722.9 KB
File name:
XA03190TEN_0224-00.pdf
XA iTEMP TMT71, TMT72, TMT82, TMT84, TMT85, TMT86
Ex db IIC T4...T6 Gb Ex tb IIIC T85…T110°C Db
Language:
English
Version:
28/09/2023
File size:
427.3 KB
File name:
XA03197TEN_0123-00.pdf
PROFIBUS PA®/FOUNDATION Fieldbus™ CSA: Control Drawing IS, NI 340200112
Language:
English
Version:
06/08/2007
File size:
96.6 KB
File name:
340200112.pdf
PROFIBUS PA®/FOUNDATION Fieldbus™ FM: Control Drawing IS, NI 340200111
Language:
English
Version:
06/08/2007
File size:
100.2 KB
File name:
340200111.pdf
ATEX Safety instructions
iTEMP® TMT84 and TMT85
Two channel temperature head transmitters with FOUNDATION Fieldbus-/PROFIBUS® PA-protocol
EN
German French
01/01/2008
Language:
English
Version:
01/01/2008
File size:
875.2 KB
File name:
XA073ra3_0108.pdf
ATEX Safety instructions
iTEMP® TMT84 and TMT85
Two channel temperature head transmitters with FOUNDATION Fieldbus-/PROFIBUS® PA-protocol
EN
German French
01/01/2008
Language:
English
Version:
01/01/2008
File size:
1.1 MB
File name:
XA074ra3_0108.pdf
iTEMP TMT71, TMT72, TMT82, TMT84, TMT85, TMT86
ATEX, IECEx: Ex db IIC T6 Gb Ex tb IIIC Txxx °C Db
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Italian Korean Lithuanian Latvian Dutch Polish Portuguese Romanian Slovak Slovenian Swedish
20/02/2023
16/08/2022
10/11/2020
01/12/2018
12/07/2016
Language:
English
Version:
20/02/2023
File size:
429.2 KB
File name:
XA01007TEN_0723-00.pdf
Control Drawing FM Intrinsical Safety, Non incendive iTEMP® TMT84 and
iTEMP® TMT85
Two channel temperature head transmitter with FOUNDATION Fiedbus-/PROFIBUS® PA protocol Installation notes for hazardous locations
Language:
English
Version:
02/12/2007
File size:
149.4 KB
File name:
340200111.pdf
Control Drawing FM XP, Non incendive, dust ignition proof, DIP ITEMP®
TMT82, TMT84, TMT85
Temperature transmitter iTEMP® TMT8x. Installation Notes for hazardous locations
Language:
English
Version:
25/04/2012
File size:
171.3 KB
File name:
340200113.pdf
Control Drawing CSA Intrinsical Safety, Non incendive iTEMP® TMT84 and
iTEMP® TMT85
Two channel temperature head transmitter with FOUNDATION Fiedbus-/PROFIBUS® PA protocol Installation notes for hazardous locations
Language:
English
Version:
02/12/2007
File size:
159.7 KB
File name:
340200112.pdf
iTEMP® TMT84, TMT85
Control Drawing CSA (XP, NI, DIP)
Installation notesfor XP class I / Div. 1 / Groups ABCD DIP Class II, III / Div. 1 / Groups EFG NI Class I /Div. 2 / Groups ABCD
Language:
English
Version:
01/02/2012
File size:
165.6 KB
File name:
340200114.pdf
Control Drawing FM XP, Non incendive, Dust Ignition Proof iTEMP® TMT82,
TMT84, TMT85
Temperature transmitter iTEMP® TMT82, TMT84, TMT85 Installation Notes for hazardous locations
Language:
English
Version:
25/04/2012
File size:
116.6 KB
File name:
340500113.pdf
Technical documentation in other languages
Language:
English
Version:
14/07/2021
File size:
478.5 KB
File name:
SD02429R09EN_0121.pdf
Automatic identification of physical objects
EN
German
10/05/2023
03/12/2021
01/11/2021
Language:
English
Version:
10/05/2023
File size:
649 KB
File name:
SD02817TEN_0323-00.pdf
Integration Tutorial ME01
Mitsubishi Electric MELSEC System Q and PROFIBUS for Water &
Wastewater Industry
This document provides a step by step description on how to integrate Endress+Hauser PROFIBUS devices with the Mitsubishi Electric MELSEC Q System. All content of this document is jointly developed, reviewed and approved by Mitsubishi Electric and Endress+Hauser as a common deliverable of Open Integration.
Language:
English
Version:
20/11/2015
File size:
5.3 MB
File name:
SD01432SEN_0215.pdf
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.12.00
EN
German
30/07/2015
13/01/2015
15/04/2014
07/01/2014
18/03/2013
Language:
English
Version:
30/07/2015
File size:
438.9 KB
File name:
MI00095S_04_en_10.15.pdf
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.08.00
EN
German
30/07/2015
05/02/2015
10/07/2014
08/04/2014
18/03/2013
Language:
English
Version:
30/07/2015
File size:
253 KB
File name:
MI00099S_04_en_09.15.pdf
Search spare parts by number in drawing
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Fixing kit cpl. TMT8x/7x (european)
Fixing kit cpl. TMT8x/7x USA(american)
Spare parts kit sealing TA30A/TA30D
Set O-ring 74x3 75o VMQ Silicon (5 pcs.)
Adapter DIN rail mounting
Set mounting bracket wall cpl. W06 neutr
Set mounting bracket pipe W06 neutral
Display Unit Head Transmitter
Plug for Thermometer + Transmitter
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all