Documents / Manuals / Software
-
Promass 63Technical Information
Coriolis Mass Flow Measurement System Promass 63, simultaneous measurement of mass, density and
temperature for liquids and gases.Technical Information (TI) -
Promass 63PROFIBUS-DP/-PAOperating Instructions
Coriolis Mass Flow Measuring System (with PROFIBUS-DP/-PA interface) for measuring the mass flow rate, density and temperature of
fluids and gases.Operating Instruction (BA) -
Promass 63Operating Instructions
Coriolis Mass Flow Measuring System for measuring the mass flow rate, density and temperature of fluids and gases.
Operating Instruction (BA) -
Replacing connecting cable
Installation Instructions
Promass 60, 63, 64, 80, 83, 84
Installation Instructions (EA) -
Change of device roots in CER database
Installation Instructions
Promag 30, 33, 10, 50, 53, Promass 60, 63, 80, 83, Prowirl 70, 77, 72,
73Installation Instructions (EA) -
Promass 63ATEX II 3GEx documentation
Ex-Dokumentation zur Betriebsanleitung BA014D, BA033D.
Ex documentation for the operating instruction BA014D,
BA033D.
Documentation Ex relative à la mise en service BA014D, BA033D.Ex Safety Instructions (XA) -
Promass 63ATEX II 2GEx documentation
Ex-Dokumentation zur Betriebsanleitung BA014D, BA033D.
Ex documentation for the operating instruction BA014D,
BA033D.
Documentation Ex relative à la mise en service BA014D, BA033D.Ex Safety Instructions (XA) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Juice application: Raw juice, Application 2
Meas. point 2: BRIX-measurement raw juice
Industry Solutions (SO)English -
Juice application: Mixing continuous, Application 3
Meas. point 3: dosing of small components
Industry Solutions (SO)English -
Juice application: Sugar dissolving, Application 4
Meas. point 4: BRIX measurement sugar sirup
Industry Solutions (SO)English -
Juice application: Mixing batch, Application 2
Meas. point 2: flow measurement recipe components
Industry Solutions (SO)English -
Juice application: Concentrate storage, Application 7
Meas. point 4: flow measurement concentrate
Industry Solutions (SO)English -
Juice application: Mixing continuous, Application 2
Meas. point 2: flow measurement recipe components
Industry Solutions (SO)English -
Juice application: Mixing continuous, Application 4
Meas. point 4: BRIX measurement final product
Industry Solutions (SO)English -
Juice application: Juice concentration, Application 2
Meas. point 2: density measurement of the juice concentrate
Industry Solutions (SO)English -
Brewery application: Brewhouse, Application 14
Meas. Point 12: massflow measurement hopextract
Industry Solutions (SO)English -
Flow measurement in utilities - for the US Market
Energy management in your hands - customized solutions for
compressed air, gas, steam and waterCompetence Brochure (CP)12/10English -
Modern measurement on filling machines
Filling, cleaning and sterilization
Competence Brochure (CP)07/10English -
Geräteintegration in eine Biodiesel-Anlage. Fallbeispiel Engineering
Integration verschiedener Messgeräte und Aktoren in der Campa
Biodiesel-Anlage, Ochsenfurt, Deutschland. Die Campa AG mit Sitz in Oc
hsenfurt bei
Würzburg zählt bei Produktion sowie im
internationalem Handel und Vertrieb zu
den innovativen Pionierunternehmender
jungen Biokraftstoffindustrie.Case Studies (CS)04/07German -
Device integration into a biodiesel plant
Case Study Engineering
Integration of various measurement devices and actuators at Campa
Biodiesel Plant, Ochsenfurt, GermanyCase Studies (CS)04/07English -
GSD Single, GSD_EH_PA_FL_Promass_0x1506_V03_02_00_PALIB, 22.04.2014 (Flow
, Promass, 0x1506b)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)3.02.00Language neutral -
GSD Single, GSD_EH_PA_FL_Promass_0x1506_V03_00_03_PALIB, 22.04.2014 (Flow
, Promass, 0x1506b)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)3.00.00Language neutral -
EDD Single, PDM_DP_FL_Promass63_0x1512_na_0x01, 25.01.2019 (Flow, Promass, 0x1512)
PROFIBUS DP,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promass63_0x1506b_na_0x01, 25.01.2019 (Flow, Promass, 0x1506b)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promass_63_PA_V3_00_xx, 20.10.2020 (Flow, Promass, 0x1506b)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, Promass_63_DP_V3_02_00, 28.10.2020 (Flow, Promass, 0x1512)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, Promass_63_PA_V3_02_00, 20.10.2020 (Flow, Promass, 0x1506b)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, Promass_63_V2_02_xx, 23.10.2020 (Flow, Promass, 0x0034)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, Promass_63_V3_02_00, 23.10.2020 (Flow, Promass, 0x0034)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, Promass_63_V3_00_xx, 23.10.2020 (Flow, Promass, 0x0034)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, Promass_63_V3_03_01, 28.10.2020 (Flow, Promass, 0x0034)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Promass 63, Promass 83, Promass 84, Promass F
Product Code: 63F-, 83F-, 84F-, 8F3B-, 8F5B-
Region/Country: Canada
Approval Agency: Measurement Canada (MC)
Approval Number: AV-2374CMetrologyEnglish
Accessories / Spare parts
-
-
Order code 50093554
Kit cable Promass remote version 10m
-
Order code 50098567
Kit cable PROMASS remote version 10m Ex
-
Order code 50093573
Kit cable Promass remote version 20m
-
Order code 50098568
Kit cable PROMASS remote version 20m Ex
-
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-