Deltabar S PMD70
This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Documents / Manuals / Software
-
Deltatop
Differential pressure flow measurement with Pitot tubes and Deltabar
differential pressure transmitterTechnical Information (TI) -
Deltatop
Differential pressure flow measurement with orifices and Deltabar
differential pressure transmitterTechnical Information (TI) -
Deltabar S
PMD75, FMD77, FMD78
Differential pressure measurement and pressure measurement
Technical Information (TI) -
Deltabar S FMD77, FMD78, PMD75
HART V02.30.zz
Operating Instructions
Differential pressure transmitter with metal sensors
Operating Instruction (BA) -
Cerabar S / Deltabar S / Deltapilot S, Description of device functions
FOUNDATION Fieldbus
V 04.00.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Cerabar S /Deltabar S /Deltapilot S
Description of device
functions
PROFIBUS PA
V04.01.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Deltabar S FMD77/78; PMD75
FOUNDATION Fieldbus (V 04.00.zz)
Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
FOUNDATION FieldbusOperating Instruction (BA) -
Deltabar S FMD77/78; PMD75
PROFIBUS PA (V 04.01.zz)
Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communication via
PROFIBUS PAOperating Instruction (BA) -
Cerabar S / Deltabar S / Deltapilot S
HART V02.30.zz
Description of Instrument Functions
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Cerabar S, Deltabar S, Deltapilot S
Cearabar S - pressure transmitter
Deltabar S - differential
pressure transmitter
Deltapilot S - hydrostatic transmitterShort Instruction (KA)12/14German , English -
Cerabar S, Deltabar S, Deltapilot S
Cerabar S, Deltabar S, Deltapilot S
Process pressure measurement/differntial pressure
measurement/hydrostatic level measurement
V 04.00.zzShort Instruction (KA)12/14German , English -
Deltabar S FMD77/78; PMD75
Brief Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
FOUNDATION FieldbusShort Instruction (KA)04/17English -
Deltabar S FMD77/78; PMD75
Brief Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
PROFIBUS PAShort Instruction (KA)04/17English -
Exchange of electronics on Cerabar S, Deltabar S, and Deltapilot S
Austausch der Elektronik am Cerabar S, Deltabar S, Deltapilot S
Exchange of electronics on Cerabar S, Deltabar S, and Deltapilot S
FMB70-, FMD72-, FMD76-, FMD77-, FMD78-, PMC71-, PMD70-, PMD75-,
PMP71-, PMP72-, PMP75-Short Instruction (KA)04/12German , English -
Exchange of sensor unit on Deltabar S PMD70
Exchange of sensor unit on Deltabar S PMD70
Short Instruction (KA)04/12German , English -
Exchange of sensor unit for separate version on Deltabar S PMD70
Exchange of sensor unit for separate version on Deltabar S PMD70
Short Instruction (KA)04/12German , English -
Deltabar S FMD77, FMD78, PMD75
HART
Brief Operating Instructions
Differential pressure transmitter with metal sensors
Short Instruction (KA)03/18English -
Cerabar S, Deltabar S, Deltapilot S
Cearabar S - pressure transmitter
Deltabar S - differential pressure transmitter
Deltapilot S - hydrostatic level measurement
V02.30.zzShort Instruction (KA)02/18German , English -
Mounting set for housing T14/15
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Aluminum housing T14
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Harting plug HAN7D
Installation instruction
Cerabar M/S, Deltabar M/S, Deltapilot M/S
Installation Instructions (EA) -
Installation instruction - Ground terminal T14/T15/T17, F30/F31
Cerabar S, Deltabar S, Deltabar, Cerabar M, Deltabar M, Deltapilot M
Installation Instructions (EA) -
Sensor assembly for separate version PMD70
Installation instruction
Deltabar S
Installation Instructions (EA) -
Push button housing
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Sensor assembly for PMD70
Installation instruction
Deltabar S
Installation Instructions (EA) -
Feed-through and adapter for T15
Installation Instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Display
Installation Instruction
Cerabar S, Deltabar, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Aluminum housing T15
Installation instruction
Deltabar S, Deltapilot S
Installation Instructions (EA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
IECEx:
Ex ia IIC T6...T4 Ga/Gb
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77/78
CSA Control Drawing
960006697 I
ISEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex nA IIC T6 Gc
GYJ14.1447 (NEPSI)Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Ex ia IIC T6...T4 Ga/Gb
IECEx KEM06.0011Ex Safety Instructions (XA) -
Safety Instructions
Cerabar S PMC71, PMP71, PMP72, PMP75
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM Control Drawing
960006703 E
ISEx Safety Instructions (XA) -
Deltabar S PMD70, PMD75, FMD77, FMD78
KEMA 03 ATEX 1561
II 1/3 D
Protection: Ex tD A20 IP67 T85°CEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/3 D Ex ta/tc IIIC T85°C Da/Dc
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 D Ex ta/tb IIIC T85°C Da/Db
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ta IIIC T130°C Da/Db (HART)
Ex ta IIIC T105°C Da/Db (PA, FF)
TÜV 13.2007 (INMETRO)Ex Safety Instructions (XA) -
Deltabar S PMD70, PMD75, FMD77, FMD78
KEMA 03 ATEX 1561
II 1/2 D
Protection: Ex tD A20 IP67 T105°CEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
FM Control Drawing
960006696 F
IS, NI, DIPEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
II 1/2 D Ex ia IIIC T85°C Da/Db
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 3 G Ex nA IIC T6 Gc
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T6...T4 Ga/Gb
TÜV 13.2007 (INMETRO)Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T4/T6 Ga/GbEx Safety Instructions (XA) -
Cerabar S PMC71, PMP71, PMP75
Deltabar S FMD77, FMD78, PMD75
CSA Control Drawing
960006717 G
ISEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
FM Control Drawing
XA01064P-B
NIEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1 G Ex ia IIC T6...T4 Ga
II 1 D Ex ia IIIC T85°C Da
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
Allgemeine bauaufsichtliche Zulassung Z-65.11-384
Certificate (ZE) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960534-2092 D
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM
Drawing No.: 960534-1092 D
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
FM
Drawing No.: 960006703 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960006697 E
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
FM
Drawing No.: 960006703 C
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP75, FMD76, FMD77, FMD78, PMD70,
PMD75
CSA
Drawing No.: 960006717 D
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
CSA
Drawing No.: 960006717 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960534-2092 B
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
CSA
Drawing No.: 960006717 C
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM
Drawing No.: 960534-1092 B
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Functional Safety Manual
Deltabar S PMD75, FMD77, FMD78
Pressure and Differential Pressure, Level and Flow Measurement
with Output Signal 4...20 mASpecial Documentation (SD) -
Interoperability Statement: Deltabar S (Evolution), FOUNDATION fieldbus
Endress+Hauser field device has been tested with Rockwell Automation
Integrated Architecture-based host system Allen-Bradley ControlLogix.
Deltabar S (Evolution), FOUNDATION fieldbus Pressure Transmitter, Device
Revision: 5, DD Revision: 1, Device ID: 0x1009, Software Revision: 2.00Special Documentation (SD) -
Deltabar S PMD70/75, FMD76/77/78
Functional Safety data sheet / Datenblatt zur Funktionalen Sicherheit
Special Documentation (SD) -
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Cerabar S PMC71, PMP71, PMP75
Manufacturer Information for users regarding software updates (NE53)
Software version 02.10.40
Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Cerabar S PMC71, PMP71, PMP75
Manufacturer Information for users regarding software updates (NE53)
Software version V4.00.10 PROFIBUS PA
Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding software updates (NE53)
Software version V02.11.00 HART
Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding software updates (NE53)
Software version V04.00.01 FF
Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding softwareupdates (NE53)
Software version V04.01.00 PA
Manufacturer Information (MI) -
Cerabar S PMC71, PMP71, PMP75,
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Manufacturer Information for users regarding softwareupdates (NE53)
Software version V03.00.00 / DevRev 6 FOUNDATION FIELDBUS
Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
Control Engineering marzec 2006
Akredytowana kalibracja przetworników ci&
347;nienia i ró
&
380;nicy ci&
347;nie&
324;Publications (PU)09/08Polish -
Nap&
281;dy i Sterowanie marzec 2007
Akredytowana kalibracja przetworników
ci&
347;nienia i ró&
380;nicy ci&
347;nie&
324;Publications (PU)08/09Polish -
Ceraphire
ceramiczne czujniki ciśnienia i różnicy ciśnień
Innowacyjne uzupełnienie dla czujników z membraną metalową.
Publications (PU)01/10Polish -
压力测量
用于过程压力、差压、液位和流量测量的专业仪表
Fields of Activities (FA)09/15Chinese -
Basınç Ölçümü
Proses basıncı, fark basınç, seviye ve akış için güçlü enstrümanlar
Fields of Activities (FA)05/15Turkish -
Druckmesstechnik
Leistungsfähige Messgeräte für Prozessdruck, Differenzdruck, Füllstand
und DurchflussFields of Activities (FA)03/17German -
Pressure measurement
American version: Powerful instruments for process pressure,
differential pressure, level
and flowFields of Activities (FA)03/17English -
Misura della pressione
Potenti strumenti per la misura della pressione di processo, pressione
differenziale,
livello e portataFields of Activities (FA)03/17Italian -
Pressure measurement
Powerful instruments for process pressure, differential pressure, level
and flowFields of Activities (FA)03/17English -
Catálogo Medición de Presión
Instrumentos para la medición de presión, presión diferencial, nivel y
caudal de procesoFields of Activities (FA)03/17Spanish -
Mesure de pression
Appareils de mesure pour la pression de process, la pression
différentielle, le niveau et le débitFields of Activities (FA)03/17fr -
Pomiar ciśnienia
Potężna aparatura do pomiaru
ciśnienia procesowego, różnicy
ciśnień, poziomu i przepływuFields of Activities (FA)03/14Polish -
Komplettpaket Druckmesstechnik
Ein Ansprechpartner - spart Zeit und reduziert Kosten
Competence Brochure (CP)05/15German -
Deltabar S Differential Pressure Transmitter via
FOUNDATION fieldbus to the PlantPAx Process Automation System
System using a 1757-FFLD or FFLDC
Integration DocumentSystem Partner (SP)03/12English -
Deltabar S Transmitter via PROFIBUS PA to the PlantPAx Process
Automation System
System using a 1788HP-EN2PAR Linking Device
Integration DocumentSystem Partner (SP)01/13English -
Deltabar S Transmitter via HART to the PlantPAx Process Automation
System
System using a ControlLogix 1756 HART Analog Input Module
Integration DocumentSystem Partner (SP)01/09English -
GSD Single, GSD_EH_PA_PR_Deltabar_0x1542_V03_00_10_PALIB, 14.04.2014 (Pre
ssure, Deltabar S, 0x1542)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)3.00.10Language neutral -
GSD Single, GSD_EH_PA_PR_DeltabarS_0x1542_0x03_0x01_PALIB, 19.05.2014 (Pr
essure, Deltabar S, 0x1542)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, AMS11_5_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_0_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.0, 10.1, 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x14_0x02, 27.02.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x16_0x03, 28.05.2015 (Pressure, Deltabar S)
HART,
PDM Version: 6.1, 8.1, 8.2.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x17_0x01, 23.04.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x0A_0x01, 06.11.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x05_0x01_FFLIB_ITK4_60, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.60Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x06_0x01_FFLIB_ITK5_01, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.01Electronic Data Description (EDD)1.00.00Language neutral -
EDD Other, EDD_FF_PR_DeltabarS_0x1009b_0x07_0x02, 12.05.2014 (Pressure, D
eltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_PR_DeltabarS_0x0017_0x15_0x04, 21.08.2019 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x03_0x02, 17.08.2015 (Pressure, Deltabar S)
PROFIBUS PA,
PDM Version: 6.0 SP5, 6.1, 8.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x15_0x07, 25.02.2015 (Pressure,
Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5, 6.1, 8.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x15_0x04, 31.03.2014 (Pressure,
Deltabar S, 0x0017)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_PR_DeltabarS_0x0017_0x15_0x04, 21.08.2019 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 10.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x05_0x01_FFLIB_ITK4_61, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.61Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x01_0x01, 04.01.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x01_0x02, 04.01.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
PDM Version: 6.0 SP3, 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x06_0x03_FFLIB_ITK5_20, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.20Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, DeltabarS_PMx7x_FF_V3_00_xx_DevRev6, 22.10.2020 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltabarS_xMD7x_FF_FW4_00_zz_Dev_Rev_7, 22.10.2020 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltabarS_xMD7x_PA_FW4_01_zz_Dev_Rev_3, 21.10.2020 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, DeltabarS_xMD7x_PA_V03_00_10, 21.10.2020 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltabarS_xMD7x_PA_V4_00_xx, 21.10.2020 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltabarS_xMD7x_HART_FW2_20_zz_Dev_Rev_22, 26.10.2020 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11, R3.12Device Type Manager (DTM)1.4.189.51Language neutral -
DTM Single, DeltabarS_xMD7x_HART_FW_2_30_zz_Dev_Rev_23, 26.10.2020 (Pressure, Deltabar S, 0x0017)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0 SP4
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.4.189.51Language neutral -
DTM Single, DeltabarS_xMD7x_V02_00, 23.10.2020 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, DeltabarS_xMD7x_V02_10_xx, 23.10.2020 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, DeltabarS_xMD7x_V01_00, 23.10.2020 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_FF_Package_Pressure_1_05_00, 29.05.2018 (Pressure)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02Faceplate1.05.00Language neutral -
Faceplate Single, PRM_FF_PR_DeltabarS_0x1009b_0x07_0x02, 07.04.2014 (Pres
sure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Cerabar, Cerabar S, Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMC71-, PMC71B-, PMD70-, PMD75-, PMP51B-, PMP71-, PMP71B-, PMP72-, PMP75-
Declaration Number: HE_01332_01.20
Manufacturer Specification: Performance characteristicsManufacturer DeclarationGerman , English -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD76-, FMD77-, FMD78-, PMC71-, PMD70-, PMD75-, PMP71-, PMP72-, PMP75-
Declaration Number: HE_00729_01.17Manufacturer DeclarationGerman , English -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
EU DeclarationGerman , English , fr -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: China
Approval Agency: ACMA
Approval Number: EC11012AMiscellaneousEnglish -
Cerabar S, Deltabar S, Deltapilot S
Product Code: PMP75-, PMP71-, PMD75-, PMD70-, PMC71-, FMD78-, FMD77-, FMB70-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex iaExplosion ProtectionPortuguese -
Cerabar S, Deltabar M, Deltabar S
Product Code: PMP75-, PMP72-, PMP71-, PMD75-, PMD70-, PMD55-, PMC71-, FMD78-, FMD77-, FMD76-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex d, Ex ia, Ex iaD 20, Ex taExplosion ProtectionRussian -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex ia IIC T6 Ga/GbExplosion ProtectionEnglish , Chinese -
Deltabar S
Product Code: PMD75-, PMD70-, FMD78-, FMD77-, FMD76-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 1 D, II 1 G
Protection: Ex ia IIC T6 Ga/GbExplosion ProtectionEnglish -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: Germany
Approval Agency: DIBt
Approval Number: Z-65.11-384Overfill PreventionGerman -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 06, DD-ITK 5.20Fieldbus ConformanceEnglish -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFILE 3.02Fieldbus ConformanceEnglish -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 06, DD-ITK 5.01Fieldbus ConformanceEnglish -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 07, DD-ITK 6.10Fieldbus ConformanceEnglish -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
Deltabar S
Product Code: FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: Kazakhstan
Approval Agency: KazInMetr
Approval Number: 12913MetrologyRussian
Accessories / Spare parts
-
-
Nr 12 Order code 52020440
Mounting set housing T14/T15 / sensor
Consists of: 2x O-ring 45.69x2.62 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 12 Order code 71020596
Mounting set housing T17 / sensor
Consists of: 2x O-ring 45.62x69x2.62 EPDM. 1x profile gasket 51.4x57.2x1.6 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 13 Order code 52022418
Push button housing, PA/FF
Consists of: push button, cover + screws. Usage: external operation, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 13 Order code 52022419
Push button housing, HART, version 1
Consists of: push button, cover + screws. Colour light grey. Usage: external operation, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 13 Order code 52024110
Push button housing, HART, version 2
Consists of: push button, cover + screws. Colour dark grey. Usage: external operation, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.
-
-
-
Order code 71111056
Housing filter VA,EPDM,F15/31/T14/17,1pc
Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
Order code 71219639
Housing filter VA, VMQ, F15, T17, 1 pc.
Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
-
-
Nr 15 Order code 52020760
Cable gland M20, gasket
Consists of: cable gland M20. O-ring 18.72x2.62 VMQ. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 15 Order code 52020761
Cable entry G1/2, gasket, adapter
Consists of: gasket 18.72x2.51 NBR. Adapter M20 > G1/2. O-ring 18.77x1.78 NBR. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 15 Order code 52020762
Plug 2/7-pole, HAN7D, gasket
Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Nr 15 Order code 52020763
Plug 3-pole, M12, gasket
Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 21 Order code 52020429
Sealing EPDM, F30/31/34, T14/15, 5 pcs.
Consists of: 5x O-ring 75.87x2.62, EPDM, PTFE, FDA. Usage: housing F30/F31/F34, T14/T15.
-
Nr 21 Order code 71206971
Sealing set FVQM, T14.5 pcs.
Consists of: 5x O-ring 75.87x2.62 FVMQ. Usage: housing T14, FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 20 Order code 52020432
Cover T14/T15 Alu, gasket
Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 52028310
Cover T14 316L, Ex d, EPDM
Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71002774
Cover T17 316L, gasket
Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71002810
Cover T17 316L, sight glass, gasket
Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.
-
Nr 20 Order code 71002811
Cover T17 316L, sight glass PC, gasket
Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.
-
Nr 20 Order code 71206965
Cover T14 316L, Ex d, FVMQ
Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.
-
Nr 20 Order code 71245249
Cover T14/T15 Alu,Exd,sight glass,gasket
Material: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71245250
Cover T14 316L, Ex d, sight glass, EPDM
Material: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 25 Order code 52020432
Cover T14/T15 Alu, gasket
Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 52028310
Cover T14 316L, Ex d, EPDM
Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 71002774
Cover T17 316L, gasket
Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Order code 71043886
Cable PE, L=2m/80inch, separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71043888
Cable PE, L=5m/200inch, separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71043889
Cable PE, L=10m/400inch,separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71070738
Cable FEP, L=5m/200inch,separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71290825
Ground terminal T14/T15/T17, F30/F31
Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.
-
-
-
Nr 25 Order code 71206965
Cover T14 316L, Ex d, FVMQ
Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.
-
-
-
Nr 20 Order code 71206968
Cover T14 316L, Ex d, sight glass, FVMQ
Material: 316L. Sight glass: mineral glass,coated. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 30 Order code 52024111
Electronics HART Ex, ext. p. b., v2.0
4-20mA, version 2.0. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 52024400
Electronics HART Ex, v2.0
4-20mA, version 2.0. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71026358
Electronics HART Ex, v2.10
4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71026359
Electronics HART Ex, ext. p. b., v2.10
4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71196092
Electronic HART Ex, v2.11
4-20mA, version 02.11.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71196093
Electronics HART Ex, ext. p. b., v2.11
4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71071824
Electronics PA, HW02.00, SW4.0
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071825
Electronics PA, ext. p.b., HW02.00,SW4.0
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071826
Electronics FF, HW2.00, SW3.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071827
Electronics FF, ext. p.b., HW2.00,SW3.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214057
Electronics PA, Ex, HW2.00, SW3.00
PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214064
Electronics PA, ext. p.b.,HW2.00, SW3.00
PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214066
Electronics FF, ext. p.b.,HW2.00, SW2.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214069
Electronics FF, HW2.00, SW2.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214890
Electronics FF, ext. p.b.,HW2.00, SW4.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.
-
Nr 30 Order code 71214892
Electronics FF, HW2.00, SW4.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.
-
Nr 30 Order code 71224775
Electronics PA, HW02.00, SW4.01
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71224776
Electronics PA, ext.p. b.,HW02.00,SW4.01
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 31 Order code 52027785
HistoROM / M-DAT, 16K
Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 35 Order code 52027691
Terminal 2-pole, RFI, FF, Ex
RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028475
Terminal 2-pole, RFI, PA, OVP, Ex
Overvoltage protection, RFI-filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028476
Terminal 2-pole, RFI, FF, OVP, Ex
Overvoltage protection, RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71121574
Terminal 2-pole, RFI, PA, Ex
RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for TIIS.
-
Nr 35 Order code 71191892
Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd
RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71191894
Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd
Overvoltage protection, RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 40 Order code 71002865
Display module VU340, Cbar/Dbar/Dpilot S
Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.
-
-
-
Nr 55 Order code 52020495
Flange NPT1/4-18,UNF7/16-20,C22.8,2pc.
Material: steel C22.8. Housing adapter mounted. Flange gasket + fixing screws M10. Usage: PMD70.
-
Nr 55 Order code 52020496
Flange NPT1/4-18,UNF7/16-20,316L,2pc.
Material: 316L. Housing adapter mounted. Flange gasket + fixing screws M10. Usage: PMD70.
-
Nr 55 Order code 52020497
Flange NPT1/4-18,mount.M10,C22.8,2pc.
Material: steel C22.8. Housing adapter mounted. Flange gasket + fixing screws M10. Usage: PMD70.
-
Nr 55 Order code 52020498
Flange NPT1/4-18, mount.M10,316L,2pc.
Material: 316L. Housing adapter mounted. Flange gasket + fixing screws M10. Usage: PMD70.
-
Nr 55 Order code 71044087
Flange NPT1/4-8,UNF7/16-20,C22.8,sep.
Material: steel C22.8. 2 pieces. Housing adapter sep. housing, mounted. Flange gasket + fixing screws M10. Usage: PMD70.
-
Nr 55 Order code 71044088
Flange NPT1/4-8, UNF7/16-20,316L,sep.
Material: 316L. 2 pieces. Housing adapter sep. housing, mounted. Flange gasket + fixing screws M10. Usage: PMD70.
-
Nr 55 Order code 71044090
Flange NPT1/4-8, mount.M10,C22.8,sep.
Material: steel C22.8. 2 pieces. Housing adapter sep. housing, mounted. Flange gasket + fixing screws M10. Usage: PMD70.
-
Nr 55 Order code 71044091
Flange NPT1/4-8, mount. M10,316L,sep.
Material: 316L. 2 pieces. Housing adapter sep. housing, mounted. Flange gasket + fixing screws M10. Usage: PMD70.
-
-
-
Order code 943165-1101
Air vent valve (1x) NPT1/4"AlloyC276
Consists of: valve spindle, Alloy. Valve bush NPT1/4, Alloy.
-
Order code 943165-1200
Air vent valve (2x) NPT1/4-18 SS316L
-
Order code 943165-1220
Air vent valve (2x) R 1/4(JIS)SS316L
Consists of: 2x valve spindle R1/4 316L. 2x valve bush R1/4 316L. Verwendung: Deltabar S.
-
-
-
Nr 57 Order code 52020774
-
Nr 57 Order code 52020775
-
Nr 57 Order code 52020776
-
Nr 57 Order code 52020777
O-ring 48.9x2.62 FKM70,degreased,4 pcs
Process gasket FKM Viton. Cleaned from oil+grease. Usage: FMD76, PMD70.
-
Nr 57 Order code 52020778
-
-
-
Nr 50 Order code PMD70X-
-
-
-
Nr 65 Order code 52020779
-
-
-
Order code 52024609
Mounting set Deltabar S, 7/16-20UNF
Screws 7/16-20UNF, stainless steel. Material: 316L. Usage: wall/pipe mounting 2", FMD77/FMD78, PMD75.
-
Order code 52024611
Mounting set Deltabar S, M10
Screws M10, stainless steel. Material: 304. Usage: wall/pipe mounting 2". FMD77/FMD78, PMD75.
-
Order code 71007843
ToF Adapter FXA291
Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.
-
Order code 71110282
Cover GT18 316L, sight glass, HNBR
Material: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Order code
Phase out spares
-
Order code
09/2018
-
-
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-