Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.

Deltabar S FMD230

Product picture of: Deltabar S FMD230

This product is no longer available.

Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

Features and specifications

Back

Details

  • Measuring principle

    Differential pressure

  • Characteristic

    Digital differential pressure transmitter for hydrostatic level measurement, capacitive sensor with flush mounted ceramic measuring diaphragm
    Safety by function monitoring and membrane detection, modular transmitter design

  • Supply voltage

    4...20mA / HART:
    11,5...45V DC
    Ex: 11,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC
    Ex: 9...24VDC

  • Reference Accuracy

    0,1%

  • Long term stability

    0,1% of URL/year
    0,25% of URL/5 years

  • Process temperature

    -40°C...85°C

  • Ambient temperature

    -40°C...85°C

  • Measuring cell

    100mbar...3bar

  • Max. Turn down

    max. 100:1

  • Max. overpressure limit

    100bar

  • Process connection

    1/4-18NPT
    RC1/4"
    Flanges (DIN, ASME, JIS)

  • Communication

    4 ... 20mA
    HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    FM
    CSA
    SIL
    WHG/overspill protection
    EN10204-3.1

  • Successor

    FMD76

  • Measuring principle

    Differential pressure

  • Characteristic / Application

    Digital differential pressure transmitter for hydrostatic level measurement, capacitive sensor with flush mounted ceramic measuring diaphragm
    Safety by function monitoring and membrane detection, modular transmitter design

  • Supply / Communication

    4...20 mA / HART:
    11,5...45V DC
    Ex: 11,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC
    Ex: 9...24VDC

  • Accuracy

    0,1%

  • Long term stability

    0,1% of URL/year
    0,25% of URL/5 years

  • Ambient temperature

    -40°C...85°C

  • Process temperature

    -40°C...85°C

  • Process pressure absolute / max. overpressure limit

    100bar

  • Pressure measuring range

    100mbar...3bar

  • Main wetted parts

    Alloy C
    316L
    Monel
    Tantal

  • Process connection

    1/4-18NPT
    RC1/4"
    Flanges (DIN, ASME, JIS)

  • Max. measurement distance

    30m H2O

  • Communication

    4 ... 20mA
    HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    FM
    CSA
    SIL
    WHG/overspill protection
    EN10204-3.1

  • Options

    digital display
    SS- or Aluminumhousing

  • Successor

    FMD76

  • Application limits

    Changing density

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • Predecessor

  • Successor

    • Simple products

    • Easy to select, install and operate

    Technical excellence

    Simplicity

    • Standard products

    • Reliable, robust and low-maintenance

    Technical excellence

    Simplicity

    • High-end products

    • Highly functional and convenient

    Technical excellence

    Simplicity

    • Specialized products

    • Designed for demanding applications

    Technical excellence

    Simplicity

    Variable

    FLEX selections Technical excellence Simplicity
    • F
    • L
    • E
    • X

    Fundamental selection

    Meet your basic measurement needs

    Technical excellence
    Simplicity
    • F
    • L
    • E
    • X

    Lean selection

    Handle your core processes easily

    Technical excellence
    Simplicity
    • F
    • L
    • E
    • X

    Extended selection

    Optimize your processes with innovative technologies

    Technical excellence
    Simplicity
    • F
    • L
    • E
    • X

    Xpert selection

    Master your most challenging applications

    Technical excellence
    Simplicity

    Variable