Analog pH sensor
Ceraliquid CPS41
Glass electrode for applications with fast-changing medium compositions or low conductivity
Ceraliquid CPS41 is the analog high performer for pH measurement in harsh chemical applications and media with low conductivity or a considerable content of organic solvents. The sensor is designed for fast response guaranteeing you high process safety even in applications with quickly changing medium compositions.
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Measurement range
pH 0-14
-
Process temperature
max. 135°C (274°F)
-
Process pressure
max. 10bar (145psi)
-
Quick selection
Individual configuration
-
Benefits
Resistant to poisoning due to constant refilling of KCl bridge electrolyte and separate reference lead
Applicable at very low conductivities (= 0.1 µS/cm) thanks to liquid KCl electrolyte
Suitable for cleaning in place (CIP) and sterilization in place (SIP)
Perfectly suited for quickly changing media: Combination of liquid...
-
Field of application
Media with very low conductivities or a considerable amount of organic solvents or alcohols and fast changing media:
Chemical industry
Power plants, e.g. boiler feed water
Life sciences, e.g. water for injection
With ATEX, FM and CSA approval for use in...
Documents / Manuals / Software
-
Technical Information CPS41, CPS41D
pH electrodes, analogue and digital with Memosens technology, with
ceramic diaphragm
and liquid KCl electrolyte, also with integrated temperature sensorTechnical Information (TI) -
pH/ORP sensors and reference half cells
Sensors with Memosens technology and analog sensors
Operating Instruction (BA) -
Ex Safety Instructions CPSXX
Sicherheitshinweise für explosionsgefährdete Bereiche.
Safety instructions for hazardous areas.
Conseils de sécurité pour zones explosibles.Ex Safety Instructions (XA) -
Analog pH/ORP sensors
Supplement to:
BA01572C
Safety instructions for electrical apparatus in explosion-hazardous
areasEx Safety Instructions (XA) -
Manufacturer Declaration
TSE/BSE free
Certificate (ZE) -
Kurzanleitung pH-/Redox-Sensoren - Short Instructions pH/ORP sensors
pH-/Redox-Sensoren - pH/ORP sensors
Special Documentation (SD) -
CPS41/41D/42/441
Adapting existing KCl supplies to new CPS4x/CPS441
Umstellen bestehender KCl-Zufuhr auf neue CPS4x/CPS441Special Documentation (SD) -
Dairy application: Cheese processing, Application 5
Meas. point 4: pH measurement of the milk
Industry Solutions (SO)English -
Brewery application: Brewhouse, Application 5
Meas. point 4: pH measurement during acification
Industry Solutions (SO)English -
Dairy application: Milk reception, Application 5
Meas. point 3: pH measuring during milk reception
Industry Solutions (SO)English -
Brewery application: Yeast propagation, Application 4
Meas. point 3: pH measurement yeast tank
Industry Solutions (SO)English -
pH 測定セレクションガイド
産業プロセスにおける pH 測定
Competence Brochure (CP)08/15Japanese -
CP00010C pH measurement in industrial processes for US market
Selection and engineering guide for your industry and application
Competence Brochure (CP)04/15English -
Measurement and control aspect of pH using inductively coupled with
bidirectional Memosens technology in flue gas desulfurization process
White Paper CP971C pH measurement and control in a power utility is an
integral part of process. The scrubber efficiency is highlydependent on
the pH. Numerous opportunities were revealed for saving time, as well as
the cost and materials in power plants. In afossil fuel power plant,
the
chemical energy stored in coal, oil, natural gas, shale oil, oxygen and
air
is converted into thermal, mechanical and finally into electrical
energy. In
other words, water is heated to steam, which spins a steam turbine. The
steam turbine drives an electrical generator.Competence Brochure (CP)04/11English -
pH-Messung in Industrieprozessen
Auswahl- und Engineering-Hilfe für verschiedene Industriebranchen und
ApplikationenCompetence Brochure (CP)03/20German -
pH measurement in industrial processes
Selection and engineering guide for different industries and
applicationsCompetence Brochure (CP)02/20English -
CP01202C pH Sensors:Calibrate, clean, perform a calibration check
or...?
This white paper will address
Knowing when to do a pH sensor calibration versus a calibration
check
How to properly clean a pH sensor
How to perform a pH sensor calibration
A decision tree for step by step guidanceCompetence Brochure (CP)02/12English -
CeraGel, CeraLiquid, Memosens, OrbiPore, OrbiSint
Product Code: CPS11-, CPS11D-, CPS12D-, CPS31D-, CPS41-, CPS41D-, CPS71D-, CPS72D-, CPS91D-
Declaration Number: HE_01182_01.19
Manufacturer Specification: RoHSManufacturer DeclarationChinese -
CeraLiquid
Product Code: CPS41-, CPS41D-
Declaration Number: FDA_00239_01.20FDA DeclarationGerman , English -
CeraGel, CeraLiquid, OrbiPore, OrbiSint, Sensor
Product Code: CPS11-, CPS12-, CPS13-, CPS41-, CPS42-, CPS64-, CPS71-, CPS72-, CPS91-, CTS1-
Declaration Number: EC_00624_01.18EU DeclarationGerman , English , fr -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Product Code: CPS491-, CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91D-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CPS16D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC RU D-DE.AD07.B.01362/19MiscellaneousRussian -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Product Code: CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS16D-, CPS491-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC D-DE.AD07.B.01363/19MiscellaneousRussian -
TopHit, Sensor, OxyMax W, OrbiTex, OrbiSint, OrbiPore, Memosens, Liquiline M, InduMax P, InduMax H, ConduMax W, ConduMax H, CeraLiquid, CeraGel
Product Code: CPS42-, CPS43-, CPS441-, CPS441D-, CPS471-, CPS471D-, CPS491-, CPS64-, CPS72-, CPS72D-, CPS91-, CPS91D-, CPS92-, CPS92D-, CPS96D-, CPS41-, CPS21-, CPS16D-, CPS13-, CPS12D-, CPS12-, CPS11D-, CPS11-, COS51D-, CM42-, CLS54-, CLS50D-, CLS50-, CLS16D-, CLS15D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex ia IIC T6 Ga, Ex ia IIC T6...T3 Ga, Ex ia IIC T6...T4 Ga, Ex ib [ia Ga] IIC T6...T4 GaExplosion ProtectionRussian -
TopHit, Sensor, OxyMax W, OxyMax H, OrbiTex, OrbiSint, OrbiPore, Memosens, Liquiline M, InduMax P, InduMax H, ConduMax W, ConduMax H, CeraLiquid, CeraGel
Product Code: CPS42-, CPS42D-, CPS43-, CPS441-, CPS441D-, CPS471-, CPS471D-, CPS491-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS72-, CPS72D-, CPS76D-, CPS91-, CPS91D-, CPS92D-, CPS96D-, CPS41D-, CPS41-, CPS21-, CPS16D-, CPS13-, CPS12D-, CPS12-, CPS11D-, CPS11-, COS81D-, COS51D-, COS22D-, CM42-, CLS82D-, CLS54-, CLS50D-, CLS50-, CLS21D-, CLS16D-, CLS15D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex ia IIC T3 Ga, Ex ia IIC T4 Ga, Ex ia IIC T6 Ga, Ex ib [ia Ga] IIC T4 Gb, Ex ib [ia Ga] IIC T6 GbExplosion ProtectionRussian -
CeraGel, CeraLiquid, OrbiPore, OrbiSint, Sensor
Product Code: CPS11-, CPS12-, CPS13-, CPS41-, CPS42-, CPS64-, CPS71-, CPS72-, CPS91-, CTS1-
Region/Country: BrazilExplosion ProtectionPortuguese -
TopHit, Sensor, OrbiSint, OrbiPore, OrbiPac, Memocheck, InduMax P, InduMax H, ConduMax W, ConduMax H, CeraLiquid, CeraGel
Product Code: CYP03D-, CTS1-, CPS92-, CPS91-, CPS72-, CPS71-, CPS491-, CPS471-, CPS441-, CPS42-, CPS41-, CPS13-, CPS12-, CPS11-, CPF82-, CPF81-, CLS54-, CLS50-, CLS21-, CLS16-, CLS15-, CLS13-, CLS12-
Region/Country: Canada
Approval Agency: CSAExplosion ProtectionEnglish -
InduMax P, Liquiline M, Memosens
Product Code: CPS41-, CPS41D-, CPS42-, CPS42D-, CPS441-, CPS441D-, CPS471-, CPS471D-, CPS491-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS72-, CPS72D-, CPS76D-, CPS91-, CPS91D-, CPS92-, CPS92D-, CPS96D-, CTS1-, CYK10-, CYP01D-, CYP02D-, OPS171D-, CLS12-, CLS13-, CLS15-, CLS15D-, CLS16-, CLS16D-, CLS21-, CLS21D-, CLS50-, CLS50D-, CLS82D-, CM42-, COS21D-, CPS171D-, CPS16D-, CPS13-, CPS12D-, CPS12-, CPS11D-, CPS11-, CPF82D-, CPF82-, CPF81D-, CPF81-, COS51D-, COS22D-
Region/Country: USA
Approval Agency: FMExplosion ProtectionEnglish
Accessories / Spare parts
-
-
Order code CPY20-
Technical buffer solution CPY20
pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. in DAkkS accredited buffer Laboratory.
-
Order code CPY4-
-